Number of pairs |
Minimum sheath thickness (mm) |
App. Outer diameter (mm) |
App. Weight (kg/km) |
5 | 1.1 | 8.0 | 87 |
10 | 1.1 | 9.5 | 120 |
20 | 1.2 | 12.0 | 194 |
30 | 1.2 | 14.1 | 250 |
50 | 1.3 | 16.5 | 368 |
100 | 1.4 | 22.0 | 673 |
200 | 1.7 | 28.8 | 1266 |
Cable Size |
No. of Pair Size of Units in Centre and Layers | |||||
Centre | 1st | 2nd | 3rd | 4th | 5th | |
2prs | 2 | - | - | - | - | - |
5prs | - | 5 | - | - | - | - |
10prs | 2 | 8 | - | - | - | - |
20prs | 1 | 6 | 13 | - | - | - |
50prs | 3 | 9 | 16 | 22 | - | - |
100prs | 2 | 8 | 14 | 20 | 25 | 31 |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 |
Pair |
1 |
2 |
3 |
4 | 5 | Last | ||||||
Wire | A | B | A | B | A | B | A | B | A | B | A | B |
Cable | ||||||||||||
5 pairs | Orange | White | Red | Grey | Blue | Brown | Red | Grey | Green | Black | ||
Centre | ||||||||||||
1pr | Orange | White | ||||||||||
2pr | Orange | White | Green | Black | ||||||||
3pr | Orange | White | Red | Grey | Green | Black | ||||||
Layers | Orange | White | Red | Grey | Blue | Brown | Red | Grey | Blue | Brown | ||
With even and odd pairs to | Green | Black |
Unit No | Colour |
1 | Blue |
2 | Orange |
3 | Green |
4 | Brown |
5 | Grey |
6 | White |
7 | Red |
8 | Black |
9 | Yellow |
10 | Violet |
Pair No | Colour of conductor insulation | |
A – wire | B – wire | |
1 | White | Blue |
2 | White | Orange |
3 | White | Green |
4 | White | Brown |
5 | White | Grey |
6 | Red | Blue |
7 | Red | Orange |
8 | Red | Green |
9 | Red | Brown |
10 | Red | Grey |
DC resistance @20°C Ohm/km Maximum Average | 91 |
DC resistance @20°C Ohm/km Maximum for 1% of cases | 96 |
Mutual Capacitance nF/km, max Average | 53 |
Mutual Capacitance nF/km, max for 1% of cases | 60 |
Pair to pair capacitance unbalance, pF max | 275 |
Insulation Resistance, 500V DC Minimum Mohm.km | 1500 |
Nominal Conductor Diameter (mm) | 0.5 |
Maximum Conductor Diameter (mm) | 0.51 |
Minimum Conductor Elongation, % | 15 |
Insulated Conductor diameter (mm) | 0.9 |
Insulation ultimate tensile force minimum (N) | 2 |
Conductors | Solid annealed bare copper conductors conforming to CCITT Yellow Book Vol. III – 2-G.541 b article, IEC 28 and ASTM B3 |
Insulation | Foam-skin polyolefin conforming to ASDM D1248 to BS 6234 Type 03 |
Cable Assembly | Twisted pairs, cabled into sub-units, cabled in a circular form |
Color Code | As indicated below |
Filling Compound |
Water resistant filling compound, applied to the gaps between the pairs |
Tape wrap | Non hygroscopic polyester tape, wrapped with 30% overlap |
Identification tape |
A suitable tape, durably marked with the manufacturer’s name, year of manufacture and type of cable is placed under the core covering |
Flooding compound |
Water resistant flooding compound, applied between the core wrap and the aluminum foil |
Screen ( Shield) | Copolymer coated aluminum foil having thickness of 0.3mm, bonded to the outer jacket, conforming to ASTM B736 |
Outer Jacket | Black PE compound |
Surface Marking | As per request |