Key Features
> View your entire system of CDU’s from a global view down to the rack level
> Auto-Discovers all your Sentry
CDU devices
> Access via Standard Network
Browser
> Outlet Clusters - Group outlets
within a CDU, across linked CDU’s or across IP addresses
> Logs: Log by start & end date
include discovery, user login, user
actions, alarm status
> Trending: Graph using a start &
end date temperature, humidity,
infeed load, infeed power, system watts/unit area & system total power
> Integrated Remote Management
of Sentry CDU’s to cycle power
and reboot selected devices
> Simple and easy to understand
alarm notification and
acknowledgement
> Real-time alarm notification
> Multiple Views: Status, current
load, power, temperature, humidity & capacity
> Email notifications via the CDU
when events occur
> SNMP traps sent via the CDU
when events occur
> Ability to import images
> Multiple user levels and
permissions
‘Quickly drill down from a global view to the rack level’
Do you have multiple Sentry™ CDUs in one or more locations that you would like to access from one central point? Would you like one central location where all alarms can be viewed and logged for reporting, email or SNMP trap notifications? No problem!
Our Sentry Power Manger (SPM) product is capable of monitoring and managing multiple Sentry devices in IP-based enterprise networks. SPM provides a global view of all Sentry CDUs along with the ability to view devices based on their temperature, humidity, current and device status. Besides managing and monitoring all alarm conditions, this information can also be used to provide reporting and trending information.
Manage Multiple Cabinet Power Distirbution Units (CDUs)
in Multiple Locations
Technical Specifications
Event Notification
> Email notification via the CDU to multiple recipients when an event occurs
> SNMP traps via the CDU when an event occurs
Ease-of-Use
> Auto-discovers each CDU for easy configuration
> Easily create a user interface that mirrors the physical deployment of the data center
> Quickly drill down from a global perspective to the rack’s actual physical location if there is a problem (quickly identify the alarm and the physical location of the CDU)
> Create outlet clusters to group outlets within a CDU, across linked
CDU’s or across enterprise locations
Multiple Reporting Options
> Reporting capabilities to produce reports on critical management parameters such a temperature, humidity and current load
> Reports on Current and Power providing the power consumption of each input, total for the rack and/or per square foot of the rack
On-Demand Accessibility
> Real-time view of all active system alarms
> Anytime, anywhere web-based views
> Manage thousands of CDUs from a single console
Compatibility
> Server Technology Sentry CDUs with firmware 5.3x or later
Web Browsers Supported:
ABU DHABI +971 2 5557351
+974 44150543
DOHA
QATAR
UAE
OMAN
MUSCAT
+968 24 750205
+971 4 3352995
+971 4 8831401
JAFZA
DUBAI
> Microsoft Internet Explorer 6.0 or later
> Mozilla Firefox 1.5 or later
> Opera 9.0 or later
> Apple Safari 2.0 or later
Supported Databases:
> SQL Server 2005
> SQL Server 2005 Express
Sentry : Power Manager
Sentry : Power Manager