Download PDF

Key Features

> View your entire system of CDU’s from a global view down to the rack level
> Auto-Discovers all your Sentry
CDU devices
> Access via Standard Network
Browser
> Outlet Clusters - Group outlets
within a CDU, across linked CDU’s or across IP addresses
> Logs: Log by start & end date
include discovery, user login, user
actions, alarm status
> Trending: Graph using a start &
end date temperature, humidity,
infeed load, infeed power, system watts/unit area & system total power
> Integrated Remote Management
of Sentry CDU’s to cycle power
and reboot selected devices
> Simple and easy to understand
alarm notification and
acknowledgement
> Real-time alarm notification
> Multiple Views: Status, current
load, power, temperature, humidity & capacity
> Email notifications via the CDU
when events occur
> SNMP traps sent via the CDU
when events occur
> Ability to import images
> Multiple user levels and
permissions

‘Quickly drill down  from a global view to the rack level

 

Do you have multiple Sentry CDUs in one or more locations that you would like to access from one central point? Would you like one central location where all alarms can be viewed and logged for reporting, email or SNMP trap notifications? No problem!

Our Sentry Power Manger (SPM) product is capable of monitoring and managing multiple Sentry devices in IP-based enterprise networks. SPM provides a global view of all Sentry CDUs along with the ability to view devices based on their temperature, humidity, current and device status. Besides managing  and monitoring all alarm conditions, this information can also be used to provide reporting and trending information.

Manage Multiple Cabinet Power Distirbution Units  (CDUs)

in Multiple Locations

Technical Specifications

 

Event Notification

> Email notification  via the CDU to multiple recipients when an event occurs

> SNMP traps  via the  CDU when an event occurs

 

Ease-of-Use

> Auto-discovers each CDU for easy  configuration

> Easily create  a user interface that mirrors the physical deployment of the data center

> Quickly drill down from a global perspective to the racks actual physical location if there is a problem (quickly identify the alarm and the physical location of the CDU)

> Create outlet clusters to group outlets within a CDU, across  linked

CDUs or across enterprise locations

 

Multiple Reporting Options

> Reporting capabilities to produce reports on critical management parameters such a temperature,  humidity and current load

> Reports on Current and Power providing the power consumption of each input, total for the rack and/or per square foot of the rack

 

On-Demand Accessibility

> Real-time view of all active system alarms

> Anytime, anywhere web-based  views

> Manage thousands of CDUs from a single console

 

Compatibility

> Server Technology Sentry CDUs with firmware  5.3x or later

 

Web Browsers Supported:

 

ABU DHABI  +971 2 5557351

+974 44150543

DOHA

QATAR

UAE

OMAN

MUSCAT

+968 24 750205

+971 4 3352995

+971 4 8831401

JAFZA

DUBAI

> Microsoft Internet Explorer 6.0 or later

> Mozilla Firefox 1.5 or later

> Opera 9.0 or later

> Apple Safari 2.0 or later

 

Supported Databases:

> SQL Server  2005

> SQL Server  2005  Express

Sentry : Power Manager

Power Manager      
Sentry™       

Sentry : Power Manager