Coupling impedance (resistance), screw terminals.
- Coarse and fine surge protection of 2-core
high-speed signalling lines.
- Installation close to protected equipment.
- For protection of communication interfaces,
mainly the RS-485 lines, of I&C, electronic security and fire detection
systems, etc. against impact of surge voltage.
- Coarse and fine surge protection in differential mode (core – core) and coarse surge protection in common mode (core – PE).
Specifications:
Parameter name |
Parameter value |
|
Type
of SPD |
C2,C3 |
|
Location
of SPD |
ST 2+3 |
|
Mounting |
DIN rail 35 mm |
|
Nominal
voltage |
Un |
6 V DC |
Maximum
operating voltage |
Uc |
6.00 V AC |
Maximum
operating voltage |
Uc |
8.50 V DC |
Nominal
load current |
IL |
0.500 A |
Treshold
frequency core-core |
f |
70.00 MHz |
Serial
resistance per core |
R |
1.60 Ω |
D1
impulse discharge current (10/350 µs) per core |
Iimp |
0.50 kA |
D1
total discharge current (10/350 µs) cores-PE |
ITotal |
1.00 kA |
C2
nominal discharge current (8/20 µs) per core |
In |
5.00 kA |
C2
total discharge current (8/20 µs) cores-PE |
ITotal |
10.00 kA |
C2
voltage protection level mode core-PE at In |
Up |
350 V |
C2
voltage protection level mode core-core at In |
Up |
26 V |
C3
voltage protection level mode core-PE at 1 kV/µs |
Up |
500 V |
C3
voltage protection level mode core-core at 1 kV/µs |
Up |
14 V |
Response
time core-core |
ta |
1 ns |
Response
time core-PE |
ta |
1 ns |
Connection
(input - output) |
terminals-terminals |
|
Cross-section
of connected conductors solid (min) |
0.14 mm2 |
|
Cross-section
of connected conductors solid (max) |
4.00 mm2 |
|
Cross-section
of connected conductors stranded (min) |
0.14 mm2 |
|
Cross-section
of connected conductors stranded (max) |
2.50 mm2 |
|
Degree
of protection |
IP 20 |
|
Range
of ambient temperatures (min/max) |
-40 / 70 °C |
|
According
to standard |
EN 61643-21+A1,A2:2013, IEC
61643-21+A1,A2:2012 |
|
ETIM
Class |
EC001625 |
|
Customs
tariff number |
85363010 |
|
EAN |
8595090551386 |
Dimensions:
Surge protection for 2-core high-speed floating signalling lines, 6 V DC, max. 0.5 A
Related Product
Combined lightning current arrester, 50 kA
Pluggable module, visual fault signalling, module locking.Two-pole high performance lightning curr..
Combined lightning current arrester, 50 kA
Pluggable module, visual fault signalling, module locking, remote fault signalling.Combination of ..
Combined lightning current arrester, 50 kA
Pluggable module, visual fault signalling, module locking.Combination of one-pole high performance..
Combined lightning current arrester,25 kA
Pluggable module, visual fault signalling, module locking, remote fault signalling.One-pole high p..