• Surge protection with voltage and current limiting, 24 V DC, max. 60 mA

Coupling impedance (resistance).

  • Special two-stage surge protection of 2-core signalling line with current limiting.
  • Installation close to protected equipment.
  • For protection of communication interfaces, mainly the measuring loops, of I<(>&<)>C, electronic security and fire detection systems, etc. against surge voltage where are long parallel lines with power network.
  •  Coarse and fine surge protection in differential mode (core – core) and coarse surge protection in common mode (core – PE).


Specifications:


Parameter name

Parameter value

Type of SPD

C2

Location of SPD

ST 2+3

Mounting

DIN rail 35 mm

Nominal voltage

Un

48 V DC

Maximum operating voltage

Uc

39.00 V AC

Maximum operating voltage

Uc

56.00 V DC

Nominal load current

IL

0.060 A

Treshold frequency core-core

f

1.80 MHz

Serial resistance per core

R

8.00 Ω

C2 nominal discharge current (8/20 µs) per core

In

5.00 kA

C2 total discharge current (8/20 µs) cores-PE

ITotal

10.00 kA

C2 voltage protection level mode core-PE at In

Up

450 V

C2 voltage protection level mode core-core at In

Up

90 V

Response time core-core

ta

1 ns

Response time core-PE

ta

100 ns

Connection (input - output)

terminals

Cross-section of connected conductors solid (max)

2.50 mm2

Cross-section of connected conductors stranded (max)

2.50 mm2

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 70 °C

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001625

Customs tariff number

85363030

EAN

8595090565970


Dimensions:



Write a review

Note: HTML is not translated!
Captcha

Surge protection with voltage and current limiting, 24 V DC, max. 60 mA

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..