• Two-stage surge protection for outdoor Ethernet devices with PoE

Surge protection for outdoor Ethernet devices with PoE.

  • Two-stage Ethernet surge protection in combination with special PoE protection.
  • Installation anywhere in the LPZ 0 zone.
  • Complies with all types of PoE/PoE+/PoE++ (according to IEEE 802.3 af/at/bt).
  • To protect Ethernet terminals with PoE (cameras, sensors, information panels, etc.).
  • For sale from 1.7.2022.


Specifications:


Parameter name

Parameter value

Type of SPD

D1,C2,C3

Location of SPD

ST 1+2+3

Maximum operating voltage core-core

Uc

8,50 V DC

Maximum operating voltage pair-pair (POE)

Uc

58,00 V DC

Nominal load current per core at 25 °C

IL

0.5 A

Treshold frequency core-core

f

500.00 MHz

Insertion attenuation at treshhold frequency

3.20 dB

C2 nominal discharge current (8/20 µs) core-core

In

0.15 kA

D1 total discharge current (10/350 µs) cores-PE

ITotal

2.00 kA

C2 total discharge current (8/20 µs) cores-PE

ITotal

10.00 kA

C2 voltage protection level mode core-core (@Uoc/In)

Up

60,00 V (0,3 kV / 0,15 kA)

C2 voltage protection level mode core-PE (@Uoc/In)

Up

700,00 V (2,5 kV / 1,25 kA)

C2 voltage protection level mode pair-pair (POE) (@Uoc/In)

Up

90,00 V (0,3 kV / 0,15 kA)

C3 voltage protection level mode core-core (@In - 1 kV/µs)

Up

45,00 V (10 A)

C3 voltage protection level mode core-PE (@In - 1 kV/µs)

Up

500,00 V (10 A)

C3 voltage protection level mode pair-pair (POE) (@In - 1 kV/µs)

Up

85,00 V (10 A)

Response time core-core

ta

1 ns

Response time core-PE

ta

100 ns

Connection (input - output)

RJ 45/RJ 45

Degree of protection

IP 66

Range of ambient temperatures (min/max)

-40 / 70 °C

Humidity

5 - 95 %

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC000943

Customs tariff number

85363010

EAN

8595090570981


Dimensions:



Write a review

Note: HTML is not translated!
Captcha

Two-stage surge protection for outdoor Ethernet devices with PoE

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..