Pluggable module,
visual fault signalling, module locking.
- Three-pole
varistor surge arrester.
- Installation
to LV installations, especially to sub-distribution boards in TN, IT systems.
- For
protection of the installations and equipments against impact of induced
overvoltages during a lightning strike or switching overvoltages.
- Suitable for the protection of wind farms and inverters, remote fault signalling.
Specifications:
ameter name |
Parameter
value |
|
Type of SPD |
T2 |
|
Mounting |
DIN
rail 35 mm |
|
Nominal voltage |
Un |
230,00–690,00
V AC |
Maximum operating voltage |
Uc |
760.00
V AC |
Maximum operating voltage of
varistor |
880
V AC |
|
Type of network |
TN |
|
Maximum overcurrent protection |
100
A gL/gG |
|
Short-circuit current rating |
ISCCR |
25.0
kA |
Nominal discharge current (8/20 µs) |
In |
20.00
kA |
Maximum discharge current (8/20 µs) |
Imax |
40.00
kA |
Voltage protection level |
Up |
3.20
kV |
Voltage protection level at 5 kA |
Up |
2.70
kV |
Response time |
ta |
25
ns |
Cross-section of connected
conductors solid (min) |
1.00
mm2 |
|
Cross-section of connected
conductors solid (max) |
35.00
mm2 |
|
Cross-section of connected
conductors stranded (min) |
1.00
mm2 |
|
Cross-section of connected
conductors stranded (max) |
25.00
mm2 |
|
Cross-section of remote indication
conductors solid (max) |
1.5
mm2 |
|
Cross-section of remote indication
conductors stranded (max) |
1.5
mm2 |
|
Fault indication |
red
indication field |
|
Remote indication |
potential-free
change-over contact |
|
Remote indication contacts |
250V/0,5A
AC,250V/0,1A DC |
|
Degree of protection |
IP
20 |
|
Range of ambient temperatures
(min/max) |
-40
/ 80 °C |
|
Humidity |
5
- 95 % |
|
According to standard |
EN
61643-11:2012, IEC 61643-11:2011 |
|
ETIM Class |
EC000941 |
|
Plug module |
SLP-600
V/0 |
|
Customs tariff number |
85363030 |
|
EAN |
8595090563051 |
Dimensions:
Replacement module: SLP-600 V/0
Varistor surge arrester, TN and IT systems, 690 V AC, 120 kA (8/20)
Related Product
AC diverter ,for suppression of AC voltage
SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..
Digital tester for status monitor of SPDs
Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..
Automatic VLD class 2 tester
Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..
Voltage limiting device, VLD of class 2.2, type VLD-O+F
Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..