• Lightning current arrester between N and PE , TT system,100 kA (10/350 µs)

Spark gap for N-PE, pluggable module, module locking.

  • For connection Type 1 SPD in 3+1 mode.
  • Installation at the boundary of zones LPZ 0 and LPZ 1 or higher, mainly to main distribution boards.
  • For protection against impact of direct or indirect lightning strikes.


Specifications:


Parameter name

Parameter value

Type of SPD

T1

Mounting

DIN rail 35 mm

Maximum operating voltage

Uc

255.00 V AC

Nominal load current for "V" connection

IL

125 A

Type of network

TT

Nominal discharge current (8/20 µs)

In

100.00 kA

Maximum discharge current (8/20 µs)

Imax

100.00 kA

Voltage protection level

Up

1.50 kV

Ability to independently switch off the following current

Ifi

0.1 kA

Response time

ta

100 ns

TOV 200 ms N-PE

1 200 V

TOV characteristic (TOV 200 ms)

withstand

Cross-section of connected conductors solid (min)

2.50 mm2

Cross-section of connected conductors solid (max)

50.00 mm2

Cross-section of connected conductors stranded (min)

2.50 mm2

Cross-section of connected conductors stranded (max)

35.00 mm2

Cross-section of remote indication conductors solid (max)

1.5 mm2

Cross-section of remote indication conductors stranded (max)

1.5 mm2

Fault indication

remote signalling of N-PE module shows the presence of the replaceable module

Remote indication

potential-free change-over contact

Remote indication contacts

250V/0,5A AC,250V/0,1A DC

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000381

Plug module

FLP-A100N V/0

Customs tariff number

85363090

EAN

8595090535744


Replacement module: FLP-A100N V/0

Write a review

Note: HTML is not translated!
Captcha

Lightning current arrester between N and PE , TT system,100 kA (10/350 µs)

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..