• Lightning current arrester for coaxial line, 440 MHz band.

Connectors N 50 ohm, lambda/4 wave lenght shortcut.

  • Lightning current arrester uses lambda/4 wave lenght shortcut.
  • Installation at the boundary of LPZ 0 and LPZ 1 zones (or higher) at the line entry into building.
  • For protection of coaxial radio lines and telecommunication devices against impact of direct or indirect lightning strike.
  • It works like band-pass (filter) for a relatively narrow frequency spectrum around the base frequency, outside of this spectrum it works like a short circuit (not suitable for combination with power supply).


Specifications:

Parameter name

Parameter value

Type of SPD

D1,C2,C3

Location of SPD

ST 1+2+3

Frequency range

f

390,00 - 490,00 MHz

Impedance

Z

50 Ω

Power (CW)

P

2 000.00 W

Insertion loss typ. (max.)

A

0,1 (0,2) dB

VSWR typ. (max.)

VSWR

1,1 (1,2)

D1 impulse discharge current (10/350 µs) core-PE

Iimp

5.00 kA

C2 nominal discharge current (8/20 µs) core-PE

In

20.00 kA

Dynamic spark-over voltage at 1kV/µs

Udyn

0.25 V

Connection (input - output)

N 50

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001466

Customs tariff number

85363030

EAN

8595090562078


Dimensions:



Write a review

Note: HTML is not translated!
Captcha

Lightning current arrester for coaxial line, 440 MHz band.

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..