• Lightning current arrester for 3-phase TN-C system, 75 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking.

  • Three-pole high performance lightning current arrester, leakage current-free.
  • Installation at the boundary of zones LPZ 0 and LPZ 1 or higher, mainly to main distribution boards.
  • For protection against impact of direct or indirect lightning strikes in wide range of applications – houses, office and industrial buildings.
  • Coordination with SPD type 2 (SLP-275 V) even without surge separating inductors.


Specifications:

rameter name

Parameter value

Type of SPD

T1

Mounting

DIN rail 35 mm

Nominal voltage

Un

230 V AC

Maximum operating voltage

Uc

260.00 V AC

Nominal load current for "V" connection

IL

125 A

Type of network

TN

Maximum overcurrent protection

250 A gL/gG

Maximum overcurrent protection for "V" connection

125 A gL/gG

Short-circuit current rating

ISCCR

50.0 kA

Total discharge current (10/350 µs)

ITotal(10/350)

75.00 kA

Lightning impulse current (10/350 µs)

Iimp

25.00 kA

Voltage protection level

Up

1.50 kV

Response time

ta

100 ns

TOV 5 s L-N

335 V

TOV characteristic (TOV 5 s)

withstand

Cross-section of connected conductors solid (min)

2.50 mm2

Cross-section of connected conductors solid (max)

50.00 mm2

Cross-section of connected conductors stranded (min)

2.50 mm2

Cross-section of connected conductors stranded (max)

35.00 mm2

Fault indication

red indication field

Remote indication

no

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

Humidity

5 - 95 %

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000381

Plug module

FLP-25-T1-V/0

Customs tariff number

85363090

EAN

8595090553007






































Dimensions:




Replacement module: FLP-25-T1-V/0

Write a review

Note: HTML is not translated!
Captcha

Lightning current arrester for 3-phase TN-C system, 75 kA (10/350 µs)

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..