• Three-Phase Network Analyser - Class A

Main Specifications:

  •  Voltage input: 3 channels: 0-275/400 VRMS (400/690 V available as an option)
  •  HF voltage input: 3 channels
  •  Current input: 4 channels, 0-6 A RMS
  •  Analogue inputs: 4 (0-20 mA)
  •  Voltage accuracy: < 0.1 %
  •  Power supply: 85-264 Vac (47-63 Hz) / 110-375 Vdc
  •  Communication: RS232 / Current loop / Ethernet port (option)
  •  Dimensions (L x H x W) in mm: 160 x 240 x 40

Description:

The MAP 640 analyzer measures and records the following parameters of HV / MV / LV electrical networks:

  •  RMS voltage
  •  Direct, negative-phase-sequence and homopolar voltage
  •  Level of unbalance
  •  Current
  •  Power measurements (P, Q, S /PF, cos phi)
  •  Energy measurements (Ea, Er, Es)
  •  Frequency
  •  THD
  •  Harmonics up to the 50th order
  •  Interharmonics
  •  Lfl, Pst and Plt flicker 

Main functions:

  •  Voltage parameters: Min., Max. and average values
  •  Current parameters: Min., Max. and average values
  •  Voltage measurements (dips, outages, interruptions and overvoltages) 
  •  1/2-1 cycle RMS
  •  HF transients (peak detection, waveform recording): 2 MHz
  •  Waveform recording: up to 12.8 kHz, configurable
  •  Possibility of configurable pre/post-triggering
  •  Transients: 78.125 µsec.
  •  Configurable analysis templates (other than EN 50160)
  •  Clock synchronization: GPS / DCF (via external coupler)
  •  Measurement of signalling voltages < 3,000 Hz
  •  PQDIF data format: available as an option
  •  Memory backup (Flash): 128 MB
  •  Internal power reserve: 10 sec.

 Advantages

  • Complies with the EN 61000-4-30 Class A standard
  • 3 U / 4 I measurement inputs
  • Fast transients (2 MHz)
  • Analysis of the parameters according to EN 50160
  • Compact and easy to install in a cabinet

Write a review

Note: HTML is not translated!
Captcha

Three-Phase Network Analyser - Class A

0 reviews / Write a review

* Required fields



Related Product

PDU 11Way Di-Strip Vertical Unswitched

PDU 11Way Di-Strip Vertical Unswitched

Optionally with lit switch, 2-pole switching19” installation option (with length 483 mm)2 versions: ..

Surge protection for 2-core floating signalling networks, 6 V DC

Surge protection for 2-core floating signalling networks, 6 V DC

Coupling impedance (resistance), screwless terminals.Coarse and fine surge protection for 2-core s..

Hydraulic tensioners for overhead lines stringing

Hydraulic tensioners for overhead lines stringing

Hydraulic machine suitable to string the conductors or OPGW of overhead transmission ..

Adjustable boom with cable guiding device

Adjustable boom with cable guiding device

SpecificationPart Number <-->kgJAD05080050-80cm10JAD06010060-100cm13JAD100170100-170cm15J..