A small fiber optic test kit,
excellent for low to medium test volume on single mode systems.
Typical test applications
- Optical
power at 25 calibrated λ, -70 to +10 dBm range.
- Optical
loss on SM fiber 1310 / 1550 nm, 70 dB range.
- Loss
testing automation & reporting with AutoTest and KITS™ software.
- Optical
continuity / tone, 12 fiber Multi-Fiber ID, 50 dB range.
- Generally
meets safety regulations & standards based test procedures.
Connector & battery summary
SC
interchangeable connector adapters.
Meter accepts PC & APC polish. Source accepts PC polish.
Meter 2 x AA alkaline. Run time >1000 hours. Micro USB pwr /charging.
Source 2 x AA alkaline. Run time >80 hours. Micro USB pwr /charging.
Includes
- DUAL
LASER OPTICAL TEST SOURCE T2822
- HANDHELD
OPTICAL POWER METER T2600
- PADDED
CANVAS CARRY POUCH OPT149
Specifications:
|
Attribute Name |
Attribute Value |
|
HANDHELD
OPTICAL POWER METER T2600 |
|
|
Detector
type |
InGaAs |
|
Calibration
accuracy |
1% (0.06
dB) |
|
Response
wavelength |
600 ~ 1700
nm |
|
Calibration
wavelengths |
780, 820,
850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450,
1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm |
|
Power range |
+10 ~ -60
dBm (for 780 ~ 980 nm) / +10 ~ -70 dBm (for 1270 ~ 1650 nm) |
|
Mid-range
linearity |
0.04 dB
(typical) |
|
Total
uncertainty |
0.3 dB
(max) |
|
Wavelength
sensitivity (± 30 nm) |
0.03 dB
(typical) |
|
ID tone
detection & Autotest sensitivity |
Up to -50
dBm |
Advanced Test Kit SM TK077
Related Product
Side Panel 41U D600 Miracel - RAL7035
Protection ratingWith installation in the miracel rack (depending on the other rack compo- nents), a..
PDU 10Way Left Angled Vertical Unswitched - 32A
XAL - Vertical Rack Mount Angled Left32 Amps total loadSupplied with 3mtrs flex to 13A UK fused plug..
AED 405.00
Cable connecting grip with two reinforced pulling eyelets
SpecificationCablePart NumberLengthBreak streghtNo point endsWireNo of wiresmm Comple..
Lightning current arrester ,replacement module, installation close to protected device, 24 V DC, max. 1 A
Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..