“VT825” is used for environment monitoring (room temperature, humidity, leakage, voltage, vibration,
access, smoke, ...), notifications (SMS, SNMP, E-mail, Video, Alarm beacons) and control of cabinets, data
centers, outdoor cabinets, telecom sites and other mission critical facilities.
HARDWARE: | SOFTWARE: | |
· CAN port for digital sensors | · Web interface | |
· 8 AutoSense RJ-12 ports for sensors | · Virtual sensors & elements: Group, E-mail, | |
· 4 dry contact inputs | · SNMP trap, SNMP Get, SMS, IP cams, PINGs, Triggers, Timers | |
· USB port for web camera or for USB flash for saving logs | · SNMP traps, SMS & E-mail notifications | |
· Two 12V 0.25A output relays | · Supports SNMP v.1, v.2c, v.3 | |
· 100 Mbit Ethernet port | · Notifications: E-mail, SMS, Syslog, Event log, | |
· External chassis earthing | SNMP Trap, SNMP Get | |
· LEDs: power, relays, errors, CAN | · Configurable embedded logic | |
· Onboard temperature sensor (1%) | · Sensor graphing | |
· Internal GSM modem extension slot (GSM modem is ordered separately) | · Multilanguage support | |
· Internal “VT10 / 1-Wire extension” slot or | | · User Access and Permissions |
· internal “VT18 / Extension slot” (extensions are ordered separately) | ||
FEATURES:
• Receive notifications of anomalous events via email, SMS / MMS, SNMP traps. • Integrates with network management systems via SNMP v.1 and Encrypted SNMP v.3. • Uses Linux operating system for maximum stability and flexibility. • Web GUI for PC, smartphones and tablets; free firmware upgrades and utilities. • Monitor up to 30 different sensors using expansion CAN units. • Compatible with full range of different third-party sensors. • Embedded web server displays sensor information and live video from connected cameras. |
SCALABILITY:
Following sensors and devices can be connected to “VT825 / Monitoring unit”:
CAN sensors | Description | |
VT408 / Extension unit | Allows to increase the number of sensors connected to any monitoring unit. Adds 8 analog sensors. | |
VT430 / Rack control unit | The unit has all possibilities for rack control, PIR sensor for door control, 2 dry contacts, temperature | |
VT440 / Dry contacts unit | Allows to increase the number of dry contacts connected to any Vutlan monitoring unit. Adds 32 or | |
VT460 / Smoke, humidity & temperature sensor | Monitors occurrence of smoke, temperature and humidity inside the building. | |
VT470 / PIR, vibration & temperature sensor | Sensor is needed for control of movement over an infra-red range and measurement of temperature and vibration indoors. | |
VT490 / Humidity & temperature sensor | Monitors temperature and humidity inside the building. |
Embedded modules (ordered separately) | Description | |
VT700 / GSM modem | Adds ability to receive and send SMS for control and notifications. | |
VT10 / 1-Wire module | VT10 adds 1-Wire port to the system. Refer to www.vutlan.com for available 1-Wire Vutlan sensors. |
Analog sensors | Description | |
VT11 / Dry contact OUT | | Switchable contact. Can be used together with equipment, for example for switching ON/OFF air conditioners |
VT420 / Converter 4-20mA | | Converter of current loop 4-20mA |
VT500 / Temperature sensor | | For measurement of temperature indoors |
VT501 / Outdoor temperature sensor | | For measurement of temperature outdoors |
VT510 / Humidity sensor | | Measures relative humidity 10-95% indoors with relative accuracy 5%. |
VT520 / AC voltage monitor | | Measures AC 110-240V |
VT530 / Access sensor | | Sensor controls the status of a door or a window: opened, closed |
VT540 / Vibration sensor | | Detects vibration, allows daisy chain connection |
Remote monitoring unit - VT825
Related Product
Snap Shot Cable Fault Finder And Length Measurement TDR
Works on energized cablesFinds cable length or distance to fault from one endMeasures cable distance..
AED 1,224.60
Blank Panel 1U DAFCAB - RAL900
Used for covering the blank space in CabinetsMaterial of Construction1.2 mm thick CRCA Sheet Steel o..
AED 12.00
Bracket Cable Bearer No.3: 115mm
Cable bracket and bearerManufactured from galvanised mild steel to BS EN ISO 1461 : 1999Mounted to t..
23B022 Set of 4 Straight Hemostats 3-1/2, 5, 6, 7"
Specifications Overall Length3-1/2, 5, 6, 7"Length 13-1/2, 5, 6, 7”MaterialStainless SteelNumbe..