•  Surge arrester for single-phase system TT, 40 kA (8/20 µs)

Pluggable module, visual fault signalling, module locking, remote fault signalling.

  • Combination of varistor surge arrester and encapsulated spark gap, connected in the 1+1 mode.
  • Installation to LV installations, especially to sub-distribution boards in TT and also TN-S systems.
  • For protection of the installations and equipments against impact of induced overvoltages during a lightning strike or switching overvoltages.


Specifications:

ameter name

Parameter value

Type of SPD

T2

Mounting

DIN rail 35 mm

Nominal voltage

Un

230 V AC

Maximum operating voltage L-N

Uc

275.00 V AC

Maximum operating voltage N-PE

Uc

255.00 V AC

Type of network

TT

Maximum overcurrent protection

160 A gL/gG

Short-circuit current rating

ISCCR

50.0 kA

Nominal discharge current (8/20 µs) L-N

In

20.00 kA

Nominal discharge current (8/20 µs) N-PE

In

20.00 kA

Maximum discharge current (8/20 µs) L-N

Imax

40.00 kA

Maximum discharge current (8/20 µs) N-PE

Imax

40.00 kA

Voltage protection level mode L-N

Up

1.35 kV

Voltage protection level mode L-PE

Up

1.50 kV

Voltage protection level mode N-PE

Up

1.50 kV

Voltage protection level at 5 kA L-N

Up

0.90 kV

Ability to independently switch off the following current N-PE

Ifi

0.1 kA

Response time L-N

ta

25 ns

Response time N-PE

ta

100 ns

TOV 5 s L-N

335 V

TOV characteristic (TOV 5 s)

withstand

TOV 120 min L-N

440 V

TOV characteristic (120 min)

safe failure

TOV 200 ms L-PE

1 455 V

TOV 200 ms N-PE

1 200 V

TOV characteristic (TOV 200 ms)

withstand

Cross-section of connected conductors solid (min)

1.00 mm2

Cross-section of connected conductors solid (max)

35.00 mm2

Cross-section of connected conductors stranded (min)

1.00 mm2

Cross-section of connected conductors stranded (max)

25.00 mm2

Cross-section of remote indication conductors solid (max)

1.5 mm2

Cross-section of remote indication conductors stranded (max)

1.5 mm2

Fault indication L-N

red indication field

Fault indication N-PE

no

Remote indication

potential-free change-over contact

Remote indication contacts

250V/0,5A AC,250V/0,1A DC

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

Humidity

5 - 95 %

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000941

Plug module

SLP-275 V/0|SLP-NPE V/0

Customs tariff number

85363030

EAN

8595090524915


Dimensions:






Write a review

Note: HTML is not translated!
Captcha

Surge arrester for single-phase system TT, 40 kA (8/20 µs)

0 reviews / Write a review

* Required fields



Related Product

Three-phase surge protection, TN and TT, 63 A

Three-phase surge protection, TN and TT, 63 A

Pluggable module, visual fault signalling, module locking, remote fault signalling.Combination of va..

Surge arrester for three-phase system TN-S, 160 kA (8/20 µs)

Surge arrester for three-phase system TN-S, 160 kA (8/20 µs)

Pluggable module, visual fault signalling, module locking, remote fault signalling.Four-pole varis..

Surge arrester for three-phase system TN-S, 160 kA (8/20 µs)

Surge arrester for three-phase system TN-S, 160 kA (8/20 µs)

Pluggable module, visual fault signalling, module locking.Fur-pole varistor surge arrester.Install..

Varistor surge arrester, TN and IT systems, 690 V AC, 120 kA (8/20)

Varistor surge arrester, TN and IT systems, 690 V AC, 120 kA (8/20)

Pluggable module, visual fault signalling, module locking.Three-pole varistor surge arrester.Insta..