This LED & laser quad source is a general purpose test
source for multimode & single mode systems at 850, 1300 nm & 1310, 1550
nm. Typical applications include fiber optic attenuation measurement, polarity
testing and fiber identification on critical systems.
- Encircled
Flux compliant multimode source
- Easy
to use, rugged & versatile
- Long
battery life, micro USB power/charger
- Interchangeable
connectors with dust cap & tilt bail
- Superior
re-connection repeatability, < 0.1 dB
- Excellent
stability
- Autotest
& Multi-Fiber ID Tone generator
- Full
QA & test reports ISO/IEC 17025 traceable
Specifications:
|
Attribute Name |
Attribute Value |
|
Output
wavelength |
Port 1:
1310, 1550 nm Laser / Port 2: 850, 1300 nm LED |
|
Output
power |
0 dBm ±1 dB
(@ 9/125 µm for 1310, 1550 m) / -20 dBm ±1 dB (@ 62.5/125 µm for 850, 1300
nm) |
|
Adjust
output power |
Adjustable
over 7 dB in 0.01 dB steps (for 1310, 1550 nm) / Fixed (for 850, 1300 nm) |
|
Short term
stability (for 15 min, typical ±2 °C, after warm up, ORL < -25 dB) |
0.04 dB
(typical for 1310, 1550 nm) / 0.01 dB (typical for 850, 1300 nm) |
|
Stability
over temperature |
0.6 dB (for
1310, 1550 nm) / 0.35 dB (for 850, 1300 nm) |
|
Wavelength
initial tolerance (@ 25 °C) |
20 nm (for
1310, 1550 nm) |
|
Spectrum
width (FWHM) |
3 nm
(typical for 1310, 1550 nm) |
|
Wavelength
drift |
0.4 nm /°C
(typical for 1310, 1550 nm) / 0.4 nm /°C (typical for 850, 1300 nm) |
|
Mode
controlled source |
850, 1300
nm (50/125µm compliant: IEC 61280-4-1 {Ed.1.0}, TIA 526-14A & TIA
TSB-178) |
|
Reconnection
repeatability (95% confidence) |
0.1 dB (for
1310, 1550 nm Laser) / 0.05 dB (for 850, 1300 nm LED) |
|
Calibration
validity (ISO/IEC 17025) |
3 years |
|
Modulated output |
270 Hz, 1
kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones |
|
Autotest
(not available for 470, 540 nm LED sources) |
Compatible
with KI Autotest power meter port & matching λ |
|
Power |
Battery /
External power via USB |
|
Battery
types |
2x AA (LR6)
Alkaline / 2x AA NiMH AA (rechargeable via USB) |
|
Battery
life |
Laser/LED
source: 90/80 hours in Autotest, typical |
|
Auto off |
Selectable |
|
Case |
Polycarbonate
(body) / rubber (edges & corners), moisture resistance, 1-meter drop
tested |
|
Size |
190 mm x
105 mm x 35 mm |
|
Unit weight |
0.42 kg |
|
Shipping
weight |
1.5 Kg |
|
Operating /
storage temperature |
-15 to 55
°C / -25 to 70 °C |
|
Relative
humidity |
0 ~ 95 % |
|
Warranty |
3 years |
LED & Laser Quad Optical Test Source, T2824
Related Product
Plinth Fixed W600 D600 ROV RAL7032
Plinths are aesthetic and stabilizing features that are used instead of feet or castors. W..
AED 215.00
BNC Plug 75 Ohms CR/CR G31 RG11A/U
The BNC series is the most commonly used coax connector. With its bayonet coupling mechanism this co..
AED 26.67
BNC Plug Straight CR/CR G13 (0.4/2.5)
The BNC series is the most commonly used coax connector. With its bayonet coupling mechanism this co..
AED 15.30
Cable pulling grip with two reinforced pulling eyelets, lateral opening
Hand woven galvanised steel wire mesh with two wires to join the grip together and a Talurit couplin..