• Pocket Fiber Optic Power Meter, T9600A

General power meter for Multimode and Singlemode applications (Single fiber). A simple and reliable optical power meter for testing power and loss on typical multimode & single mode fiber optic systems. It provides high accuracy and simplicity of use.

  • 8 calibration λ, ±2% accuracy, ISO/IEC 17025 traceable
  • Small size, easy to use, rugged & reliable
  • dBm / dB / linear, 0.01 dB resolution
  • Display hold & max/min recording
  • Tone detector with Multi-Fiber ID
  • Easy to use TamperLock mode
  • Interchangeable connectors
  • Full QA reports

 

Specifications:

 

Attribute Name

Attribute Value

Detector type

InGaAs

Response wavelength

600 ~ 1700 nm

Calibration wavelengths

850, 1300, 1310, 1390, 1490, 1550, 1610, 1625 nm

Power range

+5 ~ -60 dBm

Mid-range linearity

0.04 dB (typical)

Total uncertainty

0.3 dB (max)

Wavelength sensitivity (± 30 nm)

0.02 dB (typical)

ID tone detection sensitivity

up -50 dBm

Accuracy

±2 %

Calibration validity

3 Years (ISO/IEC 17025)

Resolution

0.01 dB

Polarization sensitivity

< 0.05 dB (typical)

Tone detection

200 ~ 2500 Hz ± 2 %

Power

2 x AAA (LR-03) Alkaline

Battery life

300 Hours

Auto-off

Selectable

Size

124 x 81 x 25 mm

Unit weight

0.15 kg

Shipping weight

0.5 kg

Operating / storage temperatures

-15 to 55 / -25 to 70 °C

Relative humidity

0 ~ 95 %

Warranty

3 Years

 

Write a review

Note: HTML is not translated!
Captcha

Pocket Fiber Optic Power Meter, T9600A

0 reviews / Write a review

* Required fields



Related Product

Cable 2C, 14AWG, Shielded, PVC R60052-1A -305m/Roll

Cable 2C, 14AWG, Shielded, PVC R60052-1A -305m/Roll

2/C 14 AWG SHIELDED COMMERCIAL AUDIO AND GENERAL PURPOSE LOW VOLTAGE POWER LIMITEDCABLE 60C 300V RIS..

AED 1,611.61

Separating inductor (bridge) for coordination of SPDs, up to 16 A.

Separating inductor (bridge) for coordination of SPDs, up to 16 A.

Coupling impedance.For coordination of SPDs type 1 and 2 or type 2 and 3.Specifications: ..

Lightning current arrester replacement module, 2-core high-speed shielding floating signalling lines, 6 V DC, max. 1 A

Lightning current arrester replacement module, 2-core high-speed shielding floating signalling lines, 6 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..

Lightning current arrester for signalling lines, 6 V DC, max. 1 A

Lightning current arrester for signalling lines, 6 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..