• Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll

Areas of Use

These shielded and Halogen Free Flame Retardant insulated cables are used as signal transmission cables in industrial applications. These can be easily used with their flexible construction in narrow applications like electronic control systems of computer or audio systems or in the communication sector, electronic circuits, measurement devices, machine design, office equipment, etc. These used for indoor applications. Screening protects the cable from the outer electrical effects. Because of the HFFR material, These don't burn easily and if these do, flames go off by themselves. These have low smoke density and these don't emit poisonous and corrosive gases during the fire. These used in buildings where there are important goods or the human population.

Cable Construction

 

Conductor

Stranded Annealed Copper (IEC/EN 60228, Class 5, 0.34 mm²: Class 2)

Insulation

HFFR (EN 50290-2-26)

Core Colors

DIN 47100 (4 cores colors, white, yellow, brown, green)

Lay-up

Cores are stranded in layers

Separator

PET Foil

Drain Wire

Stranded Tinned Copper

Screen

Al-PET Foil

Outer Sheath - Grey

HFFR (EN 50290-2-27), RAL 7001

Reference Standards

VDE 0812, TS 13755

 

Technical Properties

Operating Voltage

0.14 mm²..0.25 mm² 250 V; 0.34 mm²..1.50 mm² 300 V / 500 V; 2.50 mm²…... 450 V / 750 V

Test Voltage

0.14 mm² - 800 V; 0.22 mm² ….1.00 mm²- 1200 V; 1.50 mm²….. 2.50 mm² - 2500 V

Conductor Resistance

0.14 mm²- ≤138 Ω/km; 0.22 mm²- ≤85 Ω/km; 0.25 mm²- ≤77.8 Ω/km; 0.34 mm²- ≤56 Ω/km; 0.50 mm²- ≤39 Ω/km; 0.75 mm²- ≤26Ω/km; 1.00 mm²- ≤19.5 Ω/km; 1.50 mm²- ≤13.3 Ω/km; 2.50 mm²- ≤7.98 Ω/km

Insulation Resistance

>200 M.Ωxkm

Capacitance (@800Hz)

Core - Core: 0.14 mm²-≤80 nF/km; 0.22 mm²..0.34 mm²-≤100 nF/km; 0.50 mm²..0.75 mm²-≤110 nF/km; 1.00 mm²..1.50 mm²-≤120nF/km; 2.50 mm²- ≤140 nF/km Core-Screen: 0.14 mm²-≤120 nF/km; 0.22 mm²..0.34 mm²-≤150 nF/km; 0.50 mm²..0.75 mm²-≤170 nF/km; 1.00 mm²..1.50 mm²-≤180nF/km; 2.50 mm²- ≤240 nF/km

Indutance (approx.)

0.65 mH/km

Temperature Range

Fixed: -30 °C ........+70 °C, Flexible: -5 °C ........+70 °C

Flame Retardancy

IEC/EN 60332-1

Smoke Density

IEC/EN 61034-2

Amount of Halogen Acid Gas

IEC/EN 60754-1

Corrosive Gases Measurement

IEC/EN 60754-2

Min. Bending Radius

Fixed: 8 x Cable Diameter, Flexible: 15 x Cable Diameter

 

Write a review

Note: HTML is not translated!
Captcha

Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll

0 reviews / Write a review

  • AED 2.60

* Required fields



Related Product

Compact Rack Lamp

Compact Rack Lamp

FeaturesWith magnetic mountingEnergy-saving lampProtective contact socketOn/off switch3 m power supp..

Punch Down Tool 5pair 110 Type

Punch Down Tool 5pair 110 Type

Uses on LAN and telecom seating 4 or 5 pairs UTP (24AWG) at a time.Suitable for both 110 type cable ..

AED 224.00

Elicon Superstructure Level Trapezoid D400

Elicon Superstructure Level Trapezoid D400

ESD version for discharging electrostatic chargesFor utilizing the area above the worktop as storage..

Replacement module for BDM-048-V/2-(F)Rx

Replacement module for BDM-048-V/2-(F)Rx

SPD - for data, signalling and telecommunications lines / I&C / Spare modulesReplacement module ..