Areas
of Use
These
shielded and Halogen Free Flame Retardant insulated cables are used as signal
transmission cables in industrial applications. These can be easily used with
their flexible construction in narrow applications like electronic control
systems of computer or audio systems or in the communication sector, electronic
circuits, measurement devices, machine design, office equipment, etc. These
used for indoor applications. Screening protects the cable from the outer
electrical effects. Because of the HFFR material, These don't burn easily and
if these do, flames go off by themselves. These have low smoke density and
these don't emit poisonous and corrosive gases during the fire. These used in
buildings where there are important goods or the human population.
Cable
Construction
|
Conductor |
Stranded Annealed Copper
(IEC/EN 60228, Class 5, 0.34 mm²: Class 2) |
|
Insulation |
HFFR (EN 50290-2-26) |
|
Core Colors |
DIN 47100 (4 cores
colors, white, yellow, brown, green) |
|
Lay-up |
Cores are stranded in
layers |
|
Separator |
PET Foil |
|
Drain Wire |
Stranded Tinned Copper |
|
Screen |
Al-PET Foil |
|
Outer Sheath - Grey |
HFFR (EN 50290-2-27), RAL
7001 |
|
Reference Standards |
VDE 0812, TS 13755 |
Technical
Properties
|
Operating Voltage |
0.14 mm²..0.25 mm² 250 V;
0.34 mm²..1.50 mm² 300 V / 500 V; 2.50 mm²…... 450 V / 750 V |
|
Test Voltage |
0.14 mm² - 800 V; 0.22
mm² ….1.00 mm²- 1200 V; 1.50 mm²….. 2.50 mm² - 2500 V |
|
Conductor Resistance |
0.14 mm²- ≤138 Ω/km;
0.22 mm²- ≤85 Ω/km; 0.25 mm²- ≤77.8 Ω/km; 0.34 mm²- ≤56 Ω/km;
0.50 mm²- ≤39 Ω/km; 0.75 mm²- ≤26Ω/km; 1.00 mm²- ≤19.5 Ω/km; 1.50
mm²- ≤13.3 Ω/km; 2.50 mm²- ≤7.98 Ω/km |
|
Insulation Resistance |
>200 M.Ωxkm |
|
Capacitance (@800Hz) |
Core - Core: 0.14 mm²-≤80
nF/km; 0.22 mm²..0.34 mm²-≤100 nF/km; 0.50 mm²..0.75 mm²-≤110 nF/km; 1.00
mm²..1.50 mm²-≤120nF/km; 2.50 mm²- ≤140 nF/km Core-Screen: 0.14 mm²-≤120
nF/km; 0.22 mm²..0.34 mm²-≤150 nF/km; 0.50 mm²..0.75 mm²-≤170 nF/km; 1.00
mm²..1.50 mm²-≤180nF/km; 2.50 mm²- ≤240 nF/km |
|
Indutance (approx.) |
0.65 mH/km |
|
Temperature Range |
Fixed: -30 °C ........+70
°C, Flexible: -5 °C ........+70 °C |
|
Flame Retardancy |
IEC/EN 60332-1 |
|
Smoke Density |
IEC/EN 61034-2 |
|
Amount of Halogen Acid
Gas |
IEC/EN 60754-1 |
|
Corrosive Gases
Measurement |
IEC/EN 60754-2 |
|
Min. Bending Radius |
Fixed: 8 x Cable
Diameter, Flexible: 15 x Cable Diameter |
Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll
Related Product
PDU 8Way Left Angled Vertical W/Surge 13A - 3m
XAL - Vertical Rack Mount Angled Left16 Amps total loadSupplied with 3mtrs flex to 13A UK fused plug..
Line Jack 3/3A Secondary IDC
Line Jack 3/3A Secondary IDC..
Jensen Tools JTK-7500DBL Inch/MM Medical Equipment Kit in Double Gray Ballistic Nylon Case
SpecificationDimensions (ID) (L x W x D)15-1/4” x 10-3/4” x 6”Case StyleDouble Gray Ballistic NylonC..
Multi socket outlet ,SDP Type 3 for 19" RACK
Visual fault signalling, 3 m power supply cord, CEE 7/7 type plugRFi filter.Multiple socket outlet w..