• Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll

Areas of Use

These shielded and Halogen Free Flame Retardant insulated cables are used as signal transmission cables in industrial applications. These can be easily used with their flexible construction in narrow applications like electronic control systems of computer or audio systems or in the communication sector, electronic circuits, measurement devices, machine design, office equipment, etc. These used for indoor applications. Screening protects the cable from the outer electrical effects. Because of the HFFR material, These don't burn easily and if these do, flames go off by themselves. These have low smoke density and these don't emit poisonous and corrosive gases during the fire. These used in buildings where there are important goods or the human population.

Cable Construction

 

Conductor

Stranded Annealed Copper (IEC/EN 60228, Class 5, 0.34 mm²: Class 2)

Insulation

HFFR (EN 50290-2-26)

Core Colors

DIN 47100 (4 cores colors, white, yellow, brown, green)

Lay-up

Cores are stranded in layers

Separator

PET Foil

Drain Wire

Stranded Tinned Copper

Screen

Al-PET Foil

Outer Sheath - Grey

HFFR (EN 50290-2-27), RAL 7001

Reference Standards

VDE 0812, TS 13755

 

Technical Properties

Operating Voltage

0.14 mm²..0.25 mm² 250 V; 0.34 mm²..1.50 mm² 300 V / 500 V; 2.50 mm²…... 450 V / 750 V

Test Voltage

0.14 mm² - 800 V; 0.22 mm² ….1.00 mm²- 1200 V; 1.50 mm²….. 2.50 mm² - 2500 V

Conductor Resistance

0.14 mm²- ≤138 Ω/km; 0.22 mm²- ≤85 Ω/km; 0.25 mm²- ≤77.8 Ω/km; 0.34 mm²- ≤56 Ω/km; 0.50 mm²- ≤39 Ω/km; 0.75 mm²- ≤26Ω/km; 1.00 mm²- ≤19.5 Ω/km; 1.50 mm²- ≤13.3 Ω/km; 2.50 mm²- ≤7.98 Ω/km

Insulation Resistance

>200 M.Ωxkm

Capacitance (@800Hz)

Core - Core: 0.14 mm²-≤80 nF/km; 0.22 mm²..0.34 mm²-≤100 nF/km; 0.50 mm²..0.75 mm²-≤110 nF/km; 1.00 mm²..1.50 mm²-≤120nF/km; 2.50 mm²- ≤140 nF/km Core-Screen: 0.14 mm²-≤120 nF/km; 0.22 mm²..0.34 mm²-≤150 nF/km; 0.50 mm²..0.75 mm²-≤170 nF/km; 1.00 mm²..1.50 mm²-≤180nF/km; 2.50 mm²- ≤240 nF/km

Indutance (approx.)

0.65 mH/km

Temperature Range

Fixed: -30 °C ........+70 °C, Flexible: -5 °C ........+70 °C

Flame Retardancy

IEC/EN 60332-1

Smoke Density

IEC/EN 61034-2

Amount of Halogen Acid Gas

IEC/EN 60754-1

Corrosive Gases Measurement

IEC/EN 60754-2

Min. Bending Radius

Fixed: 8 x Cable Diameter, Flexible: 15 x Cable Diameter

 

Write a review

Note: HTML is not translated!
Captcha

Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll

0 reviews / Write a review

  • AED 2.60

* Required fields



Related Product

Knürr Elicon® Trapezoid wall corner (A1000, L460).

Knürr Elicon® Trapezoid wall corner (A1000, L460).

Specification:ESD version for discharging electrostatic charges. The ergonomically formed front ed..

Two adjustable booms with aluminium cable roller

Two adjustable booms with aluminium cable roller

Specificationø 210 - ø 110 ↔ 110 mmPart Number<-->kgJZKSE822e30-50cm12JZKSE822f50-80cm15JZKSE8..

Adaptor Angled Euro Shuttered 50x25mm For Keystone WEBB.

Adaptor Angled Euro Shuttered 50x25mm For Keystone WEBB.

Webb keystone shutter angled empty modules suits for CAT5e, CAT6 and CAT6A keystone jacks, includi..

Combination of lightning ,TN-C, 7,5 kA (10/350 µs).

Combination of lightning ,TN-C, 7,5 kA (10/350 µs).

Pluggable module, visual fault signalling, module locking, terminals for supply, onto 40 mm busbar s..