• Fiber Optic Laser Test Source, T9822A

A shirt-pocket size fiber optic laser light source ideal for general testing of single mode systems at 1310 and 1550 nm. It provides, high accuracy and simplicity of use.

  • Rugged, drop-resistant construction
  • User defeatable auto turn-off
  • Excellent stable lasers
  • Lanyard, shirt pocket clip & padded pouch
  • Tone generator & Multi-Fiber ID function
  • Easy use TamperLock mode
  • Compatible with Autotest power meters
  • Interchangeable connectors
  • Full QA reports with ISO9001 compliant calibration

Specifications:

Attribute Name

Attribute Value

Output wavelength

1310, 1550 nm Laser

Output power (@ 9/125 µm, adjustable over 3 dB in 0.1 dB steps)

0 dBm ±1 dB

Short term stability (for 15 min, typical ±2 °C, after warm-up, @ ORL < -25 dB)

0.04 dB

Stability over temperature

0.6 dB (typical)

Wavelength initial tolerance (@ 25 °C)

20 nm

Spectrum width (FWHM)

3 nm (typical)

Wavelength drift

0.4 nm /°C (typical)

Reconnection repeatability (95% confidence)

0.1 dB

Calibration validity (ISO/IEC 17025)

3 years

Modulation

270 Hz, 1 kHz, 2 kHz ±2 %

Multi-fiber ID

12 fibers

Autotest

Compatible with KI Autotest power meter port & matching λ

Power

2 x AAA (LR-03) Alkaline

Battery life

Laser/LED source: 40/35 hours (typical) in Autotest

Auto off

Selectable

Case

Polycarbonate with captive dust cap, 2.5-meter drop tested

Size

124 mm x 81 mm x 25 mm

Unit weight

0.15 kg

Shipping weight

0.3 kg

Operating / storage temperature

-15 to 55 °C / -25 to 70 °C

Relative humidity

0 ~ 95%

Warranty

3 years

 

 

Write a review

Note: HTML is not translated!
Captcha

Fiber Optic Laser Test Source, T9822A

0 reviews / Write a review

* Required fields



Related Product

Replacement module for FLP-SG50 V

Replacement module for FLP-SG50 V

Replacement module for FLP-SG50 V.Specifications: Parameter name ..

Combination of lightning ,TN-C, 7,5 kA (10/350 µs)

Combination of lightning ,TN-C, 7,5 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking, terminals for supply, onto 40 mm busbar s..

Lubricant gel format for cable laying

Lubricant gel format for cable laying

SpecificationBucket1L..

Lightning current arrester replacement module,for two 2-core signalling lines, 230 V DC, max. 0,5 A

Lightning current arrester replacement module,for two 2-core signalling lines, 230 V DC, max. 0,5 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..