• Advanced Test Kit SM TK077

A small fiber optic test kit, excellent for low to medium test volume on single mode systems.

Typical test applications

  • Optical power at 25 calibrated λ, -70 to +10 dBm range.
  • Optical loss on SM fiber 1310 / 1550 nm, 70 dB range.
  • Loss testing automation & reporting with AutoTest and KITS™ software.
  • Optical continuity / tone, 12 fiber Multi-Fiber ID, 50 dB range.
  • Generally meets safety regulations & standards based test procedures.

Connector & battery summary

SC interchangeable connector adapters.
Meter accepts PC & APC polish. Source accepts PC polish.
Meter 2 x AA alkaline. Run time >1000 hours. Micro USB pwr /charging.
Source 2 x AA alkaline. Run time >80 hours. Micro USB pwr /charging.

Includes

  • DUAL LASER OPTICAL TEST SOURCE T2822
  • HANDHELD OPTICAL POWER METER T2600
  • PADDED CANVAS CARRY POUCH OPT149

Specifications:

Attribute Name

Attribute Value

HANDHELD OPTICAL POWER METER T2600

Detector type

InGaAs

Calibration accuracy

1% (0.06 dB)

Response wavelength

600 ~ 1700 nm

Calibration wavelengths

780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm

Power range

+10 ~ -60 dBm (for 780 ~ 980 nm) / +10 ~ -70 dBm (for 1270 ~ 1650 nm)

Mid-range linearity

0.04 dB (typical)

Total uncertainty

0.3 dB (max)

Wavelength sensitivity (± 30 nm)

0.03 dB (typical)

ID tone detection & Autotest sensitivity

Up to -50 dBm

 

Write a review

Note: HTML is not translated!
Captcha

Advanced Test Kit SM TK077

0 reviews / Write a review

* Required fields



Related Product

Mountpost 41U Miracel Server Steel (4/set)

Mountpost 41U Miracel Server Steel (4/set)

For mounting trade standard 19” serversPlease order suitable assembly kit for rack widths 700 / 800P..

Knürr Elicon® VC Working Surfaces Linear (W- 2000, H- 800).

Knürr Elicon® VC Working Surfaces Linear (W- 2000, H- 800).

Specification:Single table or linked. Height-selectable in 20 mm increments from 640 to 760 mm. On..

Lightning current arrester for 2/3-core signalling lines, 12 V DC, max. 1 A

Lightning current arrester for 2/3-core signalling lines, 12 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..

Partition Walls-Top wall (W- 1600, H- 480).

Partition Walls-Top wall (W- 1600, H- 480).

Partition systems: Execution in monobloc-design. Bell-touch- connection, multi-surfaced. Wall th..