• Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll

Areas of Use

These shielded and Halogen Free Flame Retardant insulated cables are used as signal transmission cables in industrial applications. These can be easily used with their flexible construction in narrow applications like electronic control systems of computer or audio systems or in the communication sector, electronic circuits, measurement devices, machine design, office equipment, etc. These used for indoor applications. Screening protects the cable from the outer electrical effects. Because of the HFFR material, These don't burn easily and if these do, flames go off by themselves. These have low smoke density and these don't emit poisonous and corrosive gases during the fire. These used in buildings where there are important goods or the human population.

Cable Construction

 

Conductor

Stranded Annealed Copper (IEC/EN 60228, Class 5, 0.34 mm²: Class 2)

Insulation

HFFR (EN 50290-2-26)

Core Colors

DIN 47100 (4 cores colors, white, yellow, brown, green)

Lay-up

Cores are stranded in layers

Separator

PET Foil

Drain Wire

Stranded Tinned Copper

Screen

Al-PET Foil

Outer Sheath - Grey

HFFR (EN 50290-2-27), RAL 7001

Reference Standards

VDE 0812, TS 13755

 

Technical Properties

Operating Voltage

0.14 mm²..0.25 mm² 250 V; 0.34 mm²..1.50 mm² 300 V / 500 V; 2.50 mm²…... 450 V / 750 V

Test Voltage

0.14 mm² - 800 V; 0.22 mm² ….1.00 mm²- 1200 V; 1.50 mm²….. 2.50 mm² - 2500 V

Conductor Resistance

0.14 mm²- ≤138 Ω/km; 0.22 mm²- ≤85 Ω/km; 0.25 mm²- ≤77.8 Ω/km; 0.34 mm²- ≤56 Ω/km; 0.50 mm²- ≤39 Ω/km; 0.75 mm²- ≤26Ω/km; 1.00 mm²- ≤19.5 Ω/km; 1.50 mm²- ≤13.3 Ω/km; 2.50 mm²- ≤7.98 Ω/km

Insulation Resistance

>200 M.Ωxkm

Capacitance (@800Hz)

Core - Core: 0.14 mm²-≤80 nF/km; 0.22 mm²..0.34 mm²-≤100 nF/km; 0.50 mm²..0.75 mm²-≤110 nF/km; 1.00 mm²..1.50 mm²-≤120nF/km; 2.50 mm²- ≤140 nF/km Core-Screen: 0.14 mm²-≤120 nF/km; 0.22 mm²..0.34 mm²-≤150 nF/km; 0.50 mm²..0.75 mm²-≤170 nF/km; 1.00 mm²..1.50 mm²-≤180nF/km; 2.50 mm²- ≤240 nF/km

Indutance (approx.)

0.65 mH/km

Temperature Range

Fixed: -30 °C ........+70 °C, Flexible: -5 °C ........+70 °C

Flame Retardancy

IEC/EN 60332-1

Smoke Density

IEC/EN 61034-2

Amount of Halogen Acid Gas

IEC/EN 60754-1

Corrosive Gases Measurement

IEC/EN 60754-2

Min. Bending Radius

Fixed: 8 x Cable Diameter, Flexible: 15 x Cable Diameter

 

Write a review

Note: HTML is not translated!
Captcha

Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll

0 reviews / Write a review

  • AED 2.60

* Required fields



Related Product

Elicon Side Piece D800 H2064 RAL5018 (Turquoise)

Elicon Side Piece D800 H2064 RAL5018 (Turquoise)

Connector/closing side panelsVertical cable routing in the spacious cable ductSheet steel cable duct..

Cable External Jellyfilled Screened Unarmored 100Pr 0.63mm

Cable External Jellyfilled Screened Unarmored 100Pr 0.63mm

Telephone Cable with cellular polyethylene insulation, jelly filled with petroleum jelly and a ..

AED 60.50

Shelf Keyboard 1U - Foldable - RAL9005

Shelf Keyboard 1U - Foldable - RAL9005

Folding keyboard holder - DP-PV-01Allows keyboard to be placed in front of the 19" extrusionsMax. ex..

AED 139.20

Rear Module NETBOX+PROLINE 16U Wallmount W600mm D150mm

Rear Module NETBOX+PROLINE 16U Wallmount W600mm D150mm

ear Section is Heavy Duty Welded framed construction. 2,0mm thickness material welded as multi-layer..

AED 386.00