• Surge arrester for PV systems (both poles), up to 1500 V DC

Pluggable module, visual fault signalling, module locking, remote fault signalling.

  • Varistor surge arrester in 'Y' connection.
  • For protection of PV systems where the separating spark-over distance is kept or without LPS.
  • Maximum continuous operating voltage for PV application: UCPV ≥ 1.2x UOC STC.


Specifications:


Parameter name

Parameter value

Type of SPD

PV T2

Mounting

DIN rail 35 mm

Maximum operating voltage mode +/PE, -/PE

UCPV

1 500.00 V DC

Short-circuit current rating

ISCPV

10 000 A DC

Residual current mode +/PE, -/PE

IPE

0.250 mA AC

Residual current mode +/PE, -/PE

IPE

0.005 mA DC

Total discharge current (8/20 µs)

ITotal(8/20)

40.00 kA

Nominal discharge current (8/20 µs)

In

15.00 kA

Maximum discharge current (8/20 µs)

Imax

40.00 kA

Voltage protection level mode +/-

Up

6.40 kV

Voltage protection level mode +/PE, -/PE

Up

6.40 kV

Response time

ta

25 ns

Cross-section of connected conductors solid (min)

1.00 mm2

Cross-section of connected conductors solid (max)

35.00 mm2

Cross-section of connected conductors stranded (min)

1.00 mm2

Cross-section of connected conductors stranded (max)

25.00 mm2

Cross-section of remote indication conductors solid (max)

1.5 mm2

Cross-section of remote indication conductors stranded (max)

1.5 mm2

Fault indication

red indication field

Remote indication

potential-free change-over contact

Remote indication contacts

250V/0,5A AC,250V/0,1A DC

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

According to standard

EN 61643-31, IEC 61643-31

ETIM Class

EC000941

Customs tariff number

85354000

EAN

8595090543053


Dimensions:























Write a review

Note: HTML is not translated!
Captcha

Surge arrester for PV systems (both poles), up to 1500 V DC

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..