• Lightning current arrester between N and PE , TT system, 50 kA (10/350 µs)

Park gap for N-PE, pluggable module, module locking.

  • For connection Type 1 SPD in 1+1 mode.
  • Installation at the boundary of zones LPZ 0 and LPZ 1 or higher, mainly to main distribution boards.
  • For protection against impact of direct or indirect lightning strikes.


Specifications:

ameter name

Parameter value

Type of SPD

T1

Mounting

DIN rail 35 mm

Maximum operating voltage

Uc

255.00 V AC

Nominal load current for "V" connection

IL

125 A

Type of network

TT

Residual current

IPE

0.004 mA

Nominal discharge current (8/20 µs)

In

50.00 kA

Maximum discharge current (8/20 µs)

Imax

100.00 kA

Voltage protection level

Up

1.50 kV

Ability to independently switch off the following current

Ifi

0.1 kA

Response time

ta

100 ns

TOV 200 ms N-PE

1 200 V

TOV characteristic (TOV 200 ms)

withstand

Cross-section of connected conductors solid (min)

2.50 mm2

Cross-section of connected conductors solid (max)

50.00 mm2

Cross-section of connected conductors stranded (min)

2.50 mm2

Cross-section of connected conductors stranded (max)

35.00 mm2

Cross-section of remote indication conductors solid (max)

1.5 mm2

Cross-section of remote indication conductors stranded (max)

1.5 mm2

Fault indication

remote signalling of N-PE module shows the presence of the replaceable module

Remote indication

potential-free change-over contact

Remote indication contacts

250V/0,5A AC,250V/0,1A DC

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000381

Plug module

FLP-A50N V/0

Customs tariff number

85363090

EAN

8595090535737


Replacement Module:

    FLP-A50N V/0

Datasheet:

     FLP-A50N VS/NPE

Write a review

Note: HTML is not translated!
Captcha

Lightning current arrester between N and PE , TT system, 50 kA (10/350 µs)

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.


Related Product

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..