• Lightning current arrester for coaxial lines , up to 70 V

F connectors, 75 ohm.

  • Lightning current arrested with floating shielding (separated with GDT).
  • Installation at the boundary of LPZ 0 and LPZ 1 zones at the line entry into building.
  • For protection of coaxial lines of TV and CCTV systems, suitable as the 1st level of surge for protection in coordination with the SX type.
  • In the scope of delivery: universal plastic adapter for mounting on DIN rail and GND 2 holder.


Specifications:


Parameter name

Parameter value

Type of SPD

D1,C2

Location of SPD

ST 1

Mounting

DIN rail 35 mm

Maximum operating voltage

Uc

70.00 V DC

Nominal load current

IL

4.000 A

Frequency range

f

0,00 - 2150,00 MHz

Impedance

Z

75 Ω

Insertion loss

0.20 dB

VSWR typ. (max.)

VSWR

1,3

D1 impulse discharge current (10/350 µs) SH-PE

Iimp

2.50 kA

D1 impulse discharge current (10/350 µs) core-SH

Iimp

2.50 kA

C2 nominal discharge current (8/20 µs) SH-PE

In

10.00 kA

C2 nominal discharge current (8/20 µs) core-SH

In

10.00 kA

C3 voltage protection level mode SH-PE at 1 kV/µs

Up

600 V

C3 voltage protection level mode core-SH at 1 kV/µs

Up

600 V

Response time core-SH

ta

100 ns

Response time SH-PE

ta

100 ns

Connection (input - output)

F 75

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001466

Customs tariff number

85363010

EAN

8595090533870


Dimensions:



Datasheet:

     FX-090-F75-T-F/F

Write a review

Note: HTML is not translated!
Captcha

Lightning current arrester for coaxial lines , up to 70 V

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.


Related Product

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..