• Lightning current arrester for two 2-core signalling lines, max. 180 V

Pluggable module, line separated from protective earth via GDT. 

  • Lightning current arrester of two 2/3-core signalling lines.
  • Installation at the boundary of LPZ 0 and LPZ 1 zones at the line entry into building.
  •       Mainly for protection of telecommunication lines against surge voltage.


Specifications:


Parameter name

Parameter value

Type of SPD

D1,C2

Location of SPD

ST 1

Mounting

DIN rail 35 mm

Maximum operating voltage

Uc

128.00 V AC

Maximum operating voltage

Uc

180.00 V DC

Nominal load current

IL

16.000 A

Treshold frequency core-core

f

120.00 MHz

D1 impulse discharge current (10/350 µs) per core

Iimp

2.50 kA

D1 total discharge current (10/350 µs) cores-PE

ITotal

5.00 kA

C2 nominal discharge current (8/20 µs) GND-PE

In

10.00 kA

C2 nominal discharge current (8/20 µs) per core

In

10.00 kA

C2 total discharge current (8/20 µs) cores-PE

ITotal

20.00 kA

C3 voltage protection level mode GND-PE at 1 kV/µs

Up

550.00 V

C3 voltage protection level mode core-GND at 1 kV/µs

Up

550.00 V

C3 voltage protection level mode core-core at 1 kV/µs

Up

550 V

Response time core-core

ta

100 ns

Response time core-GND

ta

100 ns

Response time GND-PE

ta

100 ns

Connection (input - output)

terminals-terminals

Cross-section of connected conductors solid (min)

0.14 mm2

Cross-section of connected conductors solid (max)

4.00 mm2

Cross-section of connected conductors stranded (min)

0.14 mm2

Cross-section of connected conductors stranded (max)

2.50 mm2

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 70 °C

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001466

Plug module

BD-250-T-V/2-0

Customs tariff number

85363030

EAN

8595090555551




Dimensions:





Replacement module: BD-250-T-V/2-0


Datasheet:

     BD-250-T-V/2-F16





















Write a review

Note: HTML is not translated!
Captcha

Lightning current arrester for two 2-core signalling lines, max. 180 V

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.


Related Product

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..