Remote fault signalling.
- SPD for additional installation to devices or equipments.
- Installation to LV installations, close to protected equipment.
- For protection of all LV equipments against surge voltage.
- Non-symetrical connection.
Specifications:
|
Parameter name |
Parameter value |
|
|
Type of SPD |
T3 |
|
|
Mounting |
installation box |
|
|
Nominal voltage |
Un |
230 V AC |
|
Maximum operating voltage |
Uc |
275.00 V AC |
|
Type of network |
TN |
|
|
Maximum overcurrent protection |
B 16 A |
|
|
Short-circuit current rating |
ISCCR |
1.5 kA |
|
Nominal discharge current (8/20 µs) L-N |
In |
3.00 kA |
|
Nominal discharge current (8/20 µs) N-PE |
In |
3.00 kA |
|
Test voltage L-N |
Uoc |
6.0 kV |
|
Test voltage N-PE |
Uoc |
6.0 kV |
|
Voltage protection level mode L-N |
Up |
1.35 kV |
|
Voltage protection level mode L-PE |
Up |
1.50 kV |
|
Voltage protection level mode N-PE |
Up |
1.50 kV |
|
Response time L-N |
ta |
25 ns |
|
Response time N-PE |
ta |
100 ns |
|
TOV 5 s L-N |
335 V |
|
|
Fault indication |
open contact |
|
|
Remote indication |
potential-free open contact |
|
|
Remote indication contacts |
230V/0,5A AC,24V/0,5A DC |
|
|
Degree of protection |
IP 20 |
|
|
Range of ambient temperatures (min/max) |
-40 / 80 °C |
|
|
According to standard |
EN 61643-11:2012, IEC 61643-11:2011 |
|
|
ETIM Class |
EC000942 |
|
|
Customs tariff number |
85363010 |
|
|
EAN |
8595090519164 |
Dimensions:
Datasheet:
Module with surge protection for additional installation, remote fault signalling.
- Brand: SALTEK - Czech Republic Categories Surge Protection Devices
- Product Code: DA-275 CZS
- MPN: DA-275 CZS
Terms & Conditions
All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.
Related Product
Heavy Duty 400V Surge Protected Office Power Outlet Strip
Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..





