BNC connectors 50 ohm.
- Surge arrester, shielding connected to
protective grounding.
- Installation close to protected equipment.
- For protection of sensitive coaxial inputs of professional receivers.
Specifications:
|
Parameter name |
Parameter value |
|
|
Type
of SPD |
D1,C2,C3 |
|
|
Location
of SPD |
ST 1+2+3 |
|
|
Mounting |
DIN rail 35 mm |
|
|
Maximum
operating voltage |
Uc |
26.00 V DC |
|
Nominal
load current |
IL |
0.700 A |
|
Frequency
range |
f |
0,00 - 3000,00 MHz |
|
Impedance |
Z |
50 Ω |
|
Insertion
loss |
1.50 dB |
|
|
VSWR typ.
(max.) |
VSWR |
1,2 (1,3) |
|
D1
impulse discharge current (10/350 µs) core-PE |
Iimp |
0.50 kA |
|
C2
nominal discharge current (8/20 µs) core-PE |
In |
2.50 kA |
|
Dynamic
spark-over voltage at 1kV/µs |
Udyn |
85.00 V |
|
Response
time core-PE |
ta |
1 ns |
|
Connection
(input - output) |
BNC 50 |
|
|
Degree
of protection |
IP 20 |
|
|
Range
of ambient temperatures (min/max) |
-40 / 80 °C |
|
|
Humidity |
5 - 95 % |
|
|
According
to standard |
EN 61643-21+A1,A2:2013, IEC
61643-21+A1,A2:2012 |
|
|
ETIM
Class |
EC001625 |
|
|
Customs
tariff number |
85363010 |
|
|
EAN |
8595090541578 |
Dimensions:
Datasheet:
Surge arrester for protection of sensitive coaxial inputs ,50 Ohm
- Brand: SALTEK - Czech Republic Categories Surge Protection Devices
- Product Code: SX-090-B50-F/F
- MPN: SX-090-B50-F/F
Terms & Conditions
All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.
Related Product
Heavy Duty 400V Surge Protected Office Power Outlet Strip
Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..