For LSA-PLUS separating strips.
- Combination of coarse and fine protection of
data and I&C lines.
- Installation close to protected equipment.
- For protection of communication interfaces
and measuring lines of I&C, electronic security and fire detection systems,
etc. against impact of surge voltage.
- Coarse and fine surge protection in differential mode (core – core) and coarse protection in common mode (core – PE).
Specifications:
|
Parameter name |
Parameter value |
|
|
Type
of SPD |
C2,C3 |
|
|
Location
of SPD |
ST 2+3 |
|
|
Mounting |
LSA disconnection rail |
|
|
Maximum
operating voltage |
Uc |
25.00 V AC |
|
Maximum
operating voltage |
Uc |
36.00 V DC |
|
Nominal
load current |
IL |
0.500 A |
|
Serial
resistance per core |
R |
1.60 Ω |
|
C2
nominal discharge current (8/20 µs) per core |
In |
5.00 kA |
|
C2
total discharge current (8/20 µs) cores-PE |
ITotal |
10.00 kA |
|
C2
voltage protection level mode core-PE at In |
Up |
400 V |
|
C3
voltage protection level mode core-PE at 1 kV/µs |
Up |
350 V |
|
C3
voltage protection level mode core-core at 1 kV/µs |
Up |
48 V |
|
Response
time core-core |
ta |
1 ns |
|
Response
time core-PE |
ta |
100 ns |
|
Connection
(input - output) |
LSA disconnection rail |
|
|
Degree
of protection |
IP 20 |
|
|
Range
of ambient temperatures (min/max) |
-40 / 70 °C |
|
|
According
to standard |
EN 61643-21+A1,A2:2013, IEC
61643-21+A1,A2:2012 |
|
|
ETIM
Class |
EC001625 |
|
|
Accessories |
grounding rail |
|
|
Customs
tariff number |
85363010 |
|
|
EAN |
8595090551713 |
Dimensions:
Datasheet:
Surge protection for 2-core signal line, 24 V
- Brand: SALTEK - Czech Republic Categories Surge Protection Devices
- Product Code: CLSA-24
- MPN: CLSA-24
Terms & Conditions
All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.
Related Product
Heavy Duty 400V Surge Protected Office Power Outlet Strip
Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..