• Surge protection for 3-core signalling lines, 12 V DC, max. 370 mA

Coupling impedance (L – inductance).

  • Coarse and fine surge protection for 3-core signalling lines.
  • Cnstallation close to protected equipment.
  • For protection of communication interfaces of I&C, electronic security and fire detection systems, etc. (mainly for RS-485 interfaces) against impact of surge voltage.
  • Coarse and fine surge protection in differential mode (core – core) and coarse protection in common mode (core – PE).


Specifications: 

Parameter name

Parameter value

Type of SPD

C2,C3

Location of SPD

ST 2+3

Mounting

DIN rail 35 mm

Nominal voltage

Un

12 V DC

Maximum operating voltage

Uc

10.20 V AC

Maximum operating voltage

Uc

14.50 V DC

Nominal load current

IL

0.370 A

Treshold frequency core-core

f

0.16 MHz

Serial inductance per core

L

100.00 uH

C2 nominal discharge current (8/20 µs) per core

In

10.00 kA

C2 voltage protection level mode core-PE at In

Up

350 V

C2 voltage protection level mode core-core at In

Up

35 V

C3 voltage protection level mode core-PE at 1 kV/µs

Up

650 V

C3 voltage protection level mode core-core at 1 kV/µs

Up

20 V

Response time core-core

ta

1 ns

Response time core-PE

ta

100 ns

Connection (input - output)

terminals-terminals

Cross-section of connected conductors solid (max)

4.00 mm2

Cross-section of connected conductors stranded (max)

2.50 mm2

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001625

Customs tariff number

85363010

EAN

8595090520948


Dimensions:




Write a review

Note: HTML is not translated!
Captcha

Surge protection for 3-core signalling lines, 12 V DC, max. 370 mA

0 reviews / Write a review

* Required fields



Related Product

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications: Parameter name ..

Replacement module for SLP-PV500 V/U.

Replacement module for SLP-PV500 V/U.

Replacement module for SLP-PV1000 V/Y (S).Specifications: Parameter name ..