Pluggable module, visual fault signalling, and remote fault signalling.
- A combination of a three-pole lightning current arrester and an encapsulated efficiency spark gap, connected in the 1+1 mode.
- Installation at the boundary of zones LPZ 0 and LPZ 1 or higher.
- For protection against impact of direct or indirect lightning strikes – eg. charching stations for electrical vehicles.
- Zero leakage current.
Specifications:
|
Parameter name |
Parameter
value |
|
|
Type of SPD |
T1,T2 |
|
|
Mounting |
DIN
rail 35 mm |
|
|
Nominal voltage |
Un |
230
V AC |
|
Maximum operating voltage L-N |
Uc |
275.00
V AC |
|
Maximum operating voltage N-PE |
Uc |
255.00
V AC |
|
Type of network |
TT |
|
|
Maximum overcurrent protection |
160
A gL/gG |
|
|
Short-circuit current rating |
ISCCR |
50.0
kA |
|
Lightning impulse current (10/350
µs) L-N |
Iimp |
12.50
kA |
|
Lightning impulse current (10/350
µs) N-PE |
Iimp |
25.00
kA |
|
Nominal discharge current (8/20 µs)
L-N |
In |
30.00
kA |
|
Nominal discharge current (8/20 µs)
N-PE |
In |
30.00
kA |
|
Maximum discharge current (8/20 µs)
L-N |
Imax |
60.00
kA |
|
Maximum discharge current (8/20 µs)
N-PE |
Imax |
60.00
kA |
|
Voltage protection level mode L-N |
Up |
1.50
kV |
|
Voltage protection level mode N-PE |
Up |
1.50
kV |
|
Response time L-N |
ta |
100
ns |
|
Response time N-PE |
ta |
100
ns |
|
TOV 5 s L-N |
335
V |
|
|
TOV characteristic (TOV 5 s) |
withstand |
|
|
TOV 120 min L-N |
440
V |
|
|
TOV characteristic (120 min) |
withstand |
|
|
TOV 200 ms N-PE |
1
200 V |
|
|
TOV characteristic (TOV 200 ms) |
withstand |
|
|
Cross-section of connected
conductors solid (min) |
1.00
mm2 |
|
|
Cross-section of connected
conductors solid (max) |
35.00
mm2 |
|
|
Cross-section of connected
conductors stranded (min) |
1.00
mm2 |
|
|
Cross-section of connected
conductors stranded (max) |
25.00
mm2 |
|
|
Cross-section of remote indication
conductors solid (max) |
1.5
mm2 |
|
|
Cross-section of remote indication
conductors stranded (max) |
1.5
mm2 |
|
|
Fault indication L-N |
red
indication field |
|
|
Fault indication N-PE |
no |
|
|
Remote indication |
potential-free
change-over contact |
|
|
Remote indication contacts |
250V/0,5A
AC,250V/0,1A DC |
|
|
Degree of protection |
IP
20 |
|
|
Range of ambient temperatures (min/max) |
-40
/ 80 °C |
|
|
Humidity |
5
- 95 % |
|
|
According to standard |
EN
61643-11:2012, IEC 61643-11:2011 |
|
|
ETIM Class |
EC001457 |
|
|
Plug module |
FLP-12,5-VBH/0 |
|
|
Customs tariff number |
85363030 |
|
|
EAN |
8595090570431 |
Dimensions:
Combination of lightning current and surge arrester for one-phase aplications , 25 Ka
- Brand: SALTEK - Czech Republic Categories Surge Protection Devices
- Product Code: FLP-EV12,5-VBH/1S+1
- MPN: FLP-EV12,5-VBH/1S+1
Terms & Conditions
All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.
Related Product
Heavy Duty 400V Surge Protected Office Power Outlet Strip
Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..