• Combination of lightning ,TN and TT, 7,5 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking, onto 40 mm busbar system.

  • High performance lightning current arrester, installation at the boundary of zones LPZ 0 and LPZ 1 or higher, mainly to main distribution boards upstream power meters.
  • For protection against impact of direct or indirect lightning strikes in wide range of applications – houses, office or industrial buildings, resp. to sub- distribution boards in large buildings, for application in Germany.


Specifications:


Parameter name

Parameter value

Type of SPD

T1,T2,T3

Mounting

40 mm busbar system

Nominal voltage

Un

230 V AC

Maximum operating voltage L-N

Uc

255.00 V AC

Maximum operating voltage N-PE

Uc

255.00 V AC

Type of network

TT|TN-S

Maximum overcurrent protection

160 A gL/gG

Short-circuit current rating

ISCCR

25.0 kA

Total discharge current (10/350 µs)

ITotal(10/350)

30.00 kA

Lightning impulse current (10/350 µs) L-N

Iimp

7.50 kA

Lightning impulse current (10/350 µs) N-PE

Iimp

50.00 kA

Nominal discharge current (8/20 µs) L-N

In

20.00 kA

Nominal discharge current (8/20 µs) N-PE

In

50.00 kA

Test voltage

Uoc

10.0 kV

Total discharge current (8/20 µs)

ITotal(8/20)

100.00 kA

Maximum discharge current (8/20 µs) L-N

Imax

60.00 kA

Maximum discharge current (8/20 µs) N-PE

Imax

100.00 kA

Voltage protection level mode L-N

Up

1.50 kV

Voltage protection level mode L-PE

Up

1.50 kV

Voltage protection level mode N-PE

Up

1.50 kV

Response time L-N

ta

100 ns

Response time N-PE

ta

100 ns

TOV 5 s L-N

335 V

TOV 5 s L-PE

440 V

TOV characteristic (TOV 5 s)

withstand

TOV 120 min L-N

440 V

TOV 120 min L-PE

335 V

TOV characteristic (120 min)

withstand

TOV 200 ms N-PE

1 200 V

TOV characteristic (TOV 200 ms)

withstand

Cross-section of connected conductors solid (min)

1.00 mm2

Cross-section of connected conductors solid (max)

35.00 mm2

Cross-section of connected conductors stranded (min)

1.00 mm2

Cross-section of connected conductors stranded (max)

25.00 mm2

Fault indication

red indication field

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

Humidity

5 - 95 %

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000381

Plug module

FLP-ZP-7,5-VBH/0

Customs tariff number

85363090

EAN

8595090566236



Dimensions:





Replacement module: FLP-ZP-7,5-VBH/0

Write a review

Note: HTML is not translated!
Captcha

Combination of lightning ,TN and TT, 7,5 kA (10/350 µs)

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..