Pluggable
module, visual fault signalling, module locking.
- Two-pole
high performance lightning current arrester without follow current.
- Installation
at the boundary of zones LPZ 0 and LPZ 1 or higher, mainly to main distribution
boards.
- For
protection against impact of director or indirect lightning strikes in wide
range of applications – houses, office and industrial buildings.
- Coordination with SPD type 2 (SLP-275 V) even without surge separating inductors, no leakage current.
Specifications:
|
Parameter name |
Parameter
value |
||
|
Type of SPD |
T1 |
||
|
Mounting |
DIN
rail 35 mm |
||
|
Nominal voltage |
Un |
230
V AC |
|
|
Maximum operating voltage |
Uc |
260.00
V AC |
|
|
Nominal load current for
"V" connection |
IL |
125
A |
|
|
Type of network |
TN |
||
|
Maximum overcurrent protection |
250
A gL/gG |
||
|
Maximum overcurrent protection for
"V" connection |
125
A gL/gG |
||
|
Short-circuit current rating |
ISCCR |
50.0
kA |
|
|
Total discharge current (10/350 µs) |
ITotal(10/350) |
50.00
kA |
|
|
Lightning impulse current (10/350
µs) |
Iimp |
25.00
kA |
|
|
Voltage protection level |
Up |
1.50
kV |
|
|
Response time |
ta |
100
ns |
|
|
TOV 5 s L-N |
335
V |
||
|
TOV characteristic (TOV 5 s) |
withstand |
||
|
Cross-section of connected
conductors solid (min) |
2.50
mm2 |
||
|
Cross-section of connected
conductors solid (max) |
50.00
mm2 |
||
|
Cross-section of connected
conductors stranded (min) |
2.50
mm2 |
||
|
Cross-section of connected
conductors stranded (max) |
35.00
mm2 |
||
|
Fault indication |
red
indication field |
||
|
Remote indication |
no |
||
|
Degree of protection |
IP
20 |
||
|
Range of ambient temperatures
(min/max) |
-40
/ 80 °C |
||
|
Humidity |
5
- 95 % |
||
|
According to standard |
EN
61643-11:2012, IEC 61643-11:2011 |
||
|
ETIM Class |
EC000381 |
||
|
Plug module |
FLP-25-T1-V/0 |
||
|
Customs tariff number |
85363090 |
||
|
EAN |
8595090562597 |
||
Dimensions:
Datasheet:
Combined lightning current arrester, 50 kA
- Brand: SALTEK - Czech Republic Categories Surge Protection Devices
- Product Code: FLP-25-T1-V/2
- MPN: FLP-25-T1-V/2
Terms & Conditions
All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.
Related Product
Heavy Duty 400V Surge Protected Office Power Outlet Strip
Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..