• Combined type surge arrester ,TN and TT systems , 150 V AC, 40 kA (8/20 µs).

Pluggable module, visual fault signalling.


Combined type surge arrester (serial combination varistor+GDT).

Installation to LV installations, especially to sub-distribution boards, suitable also for measuring circuits.

For protection of the installations and equipments against impact of induced overvoltages during a lightning strike in areas with higher storm activity or switching overvoltages or as the first stage of for protection for measuring circuits.

Zero leakage current.


Specifications:


Parameter name

Parameter value

Type of SPD

T2

Mounting

DIN rail 35 mm

Nominal voltage

Un

100, 115, 120, 127 V AC

Maximum operating voltage

Uc

150.00 V AC

Maximum operating voltage

Uc

120.00 V DC

Type of network

TN|TT

Maximum overcurrent protection

125 A gL/gG

Short-circuit current rating

ISCCR

50.0 kA

Residual current

IPE

0.002 mA

Nominal discharge current (8/20 µs)

In

20.00 kA

Maximum discharge current (8/20 µs)

Imax

40.00 kA

Voltage protection level

Up

1.20 kV

Response time

ta

100 ns

TOV 5 s L-N

185 V

TOV characteristic (TOV 5 s)

withstand

TOV 120 min L-N

242 V

TOV characteristic (120 min)

withstand

Cross-section of connected conductors solid (min)

1.00 mm2

Cross-section of connected conductors solid (max)

35.00 mm2

Cross-section of connected conductors stranded (min)

1.00 mm2

Cross-section of connected conductors stranded (max)

25.00 mm2

Fault indication

red indication field

Remote indication

no

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

Humidity

5 - 95 %

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000941

Plug module

SLP-150-VB/0

Customs tariff number

85363030

EAN

8595090570530




Dimensions:





Replacement module: SLP-150-VB/0



Write a review

Note: HTML is not translated!
Captcha

Combined type surge arrester ,TN and TT systems , 150 V AC, 40 kA (8/20 µs).

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..