• Surge protection for 3-core line (combination of signal and supply lines), signal ground separated from protective earth, 24 V DC, pluggable module, floating

Pluggable module, coupling impedance (R – resistance) in part of data, line separated from protective earth via GDT.

  • Surge protection of 3-core line comprehend signal transmission and supply.
  • Installation close to protected equipment.
  • For protection of interfaces of I&C, electronic security and fire detection systems, etc., mainly for measuring circuits and sensors where signal and supply are transmited in one cable, against surge voltage.
  • Single common wire for power supply and signal transmission.


Specifications:

Parameter name

Parameter value

Cross-section of connected conductors solid (min)

0.14 mm2

Cross-section of connected conductors solid (max)

4.00 mm2

Cross-section of connected conductors stranded (min)

0.14 mm2

Cross-section of connected conductors stranded (max)

2.50 mm2

Fault indication

red indicator

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 70 °C

Humidity

5 - 95 %

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001473

Plug module

DMP-024-V/1-J-0

Nominal voltage

Un

24 V AC

Maximum operating voltage

Uc

25.00 V AC

Maximum operating voltage

Uc

36.00 V DC

Nominal load current

IL

16.000 A

Maximum overcurrent protection

16 A gL/gG nebo B 16 A

C2 nominal discharge current (8/20 µs) core-core

In

2.00 kA

Test voltage L+(L-)-PE

4.0 kV

Test voltage M-PE

4.0 kV

voltage protection level L+(L-)-PE

0.75 kV

voltage protection level M-PE

0.75 kV

C2 voltage protection level mode M-PE at In

750.00 V

C2 voltage protection level mode core-PE at In

Up

750 V

Response time L+(L-)-PE

100 ns

Response time M-PE

100 ns

Nominal voltage

Un

24 V DC

Maximum operating voltage

Uc

25.00 V AC

Maximum operating voltage

Uc

36.00 V DC

Nominal load current

IL

1.000 A

Treshold frequency core-core

4.00 MHz

Serial resistance per core

R

0.80 Ω

C2 nominal discharge current (8/20 µs) GND-PE

10.00 kA

C2 nominal discharge current (8/20 µs) core-PE

In

10.00 kA

C2 nominal discharge current (8/20 µs) per core

In

10.00 kA

C3 nominal discharge current (10/1000 µs) GND-PE

10.00 A

C3 nominal discharge current (10/1000 µs) core-PE

10.00 A

C3 voltage protection level mode GND-PE at 1 kV/µs

550.00 V

C3 voltage protection level mode core-GND at 1 kV/µs

46.00 V

Response time core-GND

1 ns

Response time GND-PE

100 ns

Customs tariff number

85363010

EAN

8595090558033


Dimensions:


Replacement Module: DMP-024-V/1-J-0

Write a review

Note: HTML is not translated!
Captcha

Surge protection for 3-core line (combination of signal and supply lines), signal ground separated from protective earth, 24 V DC, pluggable module, floating

0 reviews / Write a review

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.



Related Product

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..