Pluggable module, visual fault signalling, middle
conductor separated from protective earth via GDT.
- Surge protection for all types of LV electric
and electronic equipments against surge voltage.
- Installation to LV installations, close to
protected equipment.
- For protection of the equipments against impact of induced overvoltages during a lightning strike or switching overvoltages.
Specifications:
|
Parameter name |
Parameter value |
|
|
Type
of SPD |
T3, C2 |
|
|
Location
of SPD |
ST 2 |
|
|
Mounting |
DIN rail 35 mm |
|
|
Nominal
voltage |
Un |
12 V AC |
|
Maximum
operating voltage |
Uc |
20.00 V AC |
|
Maximum
operating voltage |
Uc |
20.00 V DC |
|
Nominal
load current |
IL |
16.000 A |
|
Maximum
overcurrent protection |
16 A gL/gG or B 16 A |
|
|
C2
nominal discharge current (8/20 µs) per core |
In |
2.00 kA |
|
Test
voltage L+ - L- |
4.0 kV |
|
|
Test
voltage L+(L-)-PE |
4.0 kV |
|
|
Test
voltage M-PE |
4.0 kV |
|
|
voltage
protection level L+ - L- |
0.18 kV |
|
|
voltage
protection level L+(L-)-PE |
0.75 kV |
|
|
voltage
protection level M-PE |
0.75 kV |
|
|
C2
voltage protection level mode core-PE at In |
750.00 V |
|
|
C2
voltage protection level mode core-PE at In |
Up |
750 V |
|
C2
voltage protection level mode core-core at In |
Up |
180 V |
|
Response
time L+ - L- |
25 ns |
|
|
Response
time L+(L-)-PE |
100 ns |
|
|
Response
time M-PE |
100 ns |
|
|
Connection
(input - output) |
terminals-terminals |
|
|
Cross-section
of connected conductors solid (min) |
0.14 mm2 |
|
|
Cross-section
of connected conductors solid (max) |
4.00 mm2 |
|
|
Cross-section
of connected conductors stranded (min) |
0.14 mm2 |
|
|
Cross-section
of connected conductors stranded (max) |
2.50 mm2 |
|
|
Fault
indication |
red indicator |
|
|
Degree
of protection |
IP 20 |
|
|
Range
of ambient temperatures (min/max) |
-40 / 70 °C |
|
|
Humidity |
5 - 95 % |
|
|
According
to standard |
EN 61643-21+A1,A2:2013, IEC
61643-21+A1,A2:2012, EN 61643-11:2012, IEC 61643-11:2011 |
|
|
ETIM
Class |
EC000942 |
|
|
Plug
module |
DP-012-V/1-0 |
|
|
Customs
tariff number |
85363030 |
|
|
EAN |
8595090556640 |
Dimensions:
Surge protection for small-voltage AC/DC power supply networks, up to 12 V DC, pluggable module
- Product Code: DP-012-V/1-F16
- MPN: DP-012-V/1-F16
Terms & Conditions
All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.
Related Product
Basic Frames doors-slide in Steel, perforated (W- W1800).
The Dacobas Avanced program offers various ways of closing the front and rear side of the basic fra..
Telescopic Slide to Adapt 19" Drawer
Telescopic slides compatible with 19" TFT drawerVariants Type 1: 600-800 mm rack depth&nb..
Multi socket outlet , SDP Type 3 for rack 19"
Visual fault signalling, 3 m power supply cord, CEE 7/7 type plug.Multiple socket outlet with integr..
Surge protection for 2-core floating signalling networks, 60 V DC, max. 0.5 A
Coupling impedance (resistance), screw terminals.Coarse and fine surge protection for 2-core signall..