• Surge protection for Ethernet without PoE, Cat.6A, LPZ1 and higher

RJ45 sockets1.

  • Fine surge protection of Ethernet line.
  • Installation close to protected equipment.
  • For protection of Ethernet line Cat. 6A against surge voltage.
  • In the scope of delivery: universal plastic adapter for mounting on DIN rail and GND 2 holder.


Specifications:

Parameter name

Parameter value

Type of SPD

C2,C3

Location of SPD

ST 2+3

Mounting

DIN rail 35 mm

Maximum operating voltage

Uc

6.00 V AC

Maximum operating voltage

Uc

8.50 V DC

Maximum operating voltage POE

Uc

6.00 V AC

Maximum operating voltage POE

Uc

8.50 V DC

Nominal load current per core at 25 °C

IL

0.5 A

Treshold frequency core-core

f

500.00 MHz

Insertion attenuation at treshhold frequency

2.90 dB

C2 nominal discharge current (8/20 µs) per core

In

0.20 kA

C2 total discharge current (8/20 µs) cores-PE

ITotal

1.60 kA

C2 voltage protection level mode (POE) at In

Up

55.00 V

C2 voltage protection level mode core-PE at In

Up

400 V

C2 voltage protection level mode core-core at In

Up

55 V

C3 voltage protection level mode (POE) at 1 kV/µs

30.00 V

C3 voltage protection level mode core-PE at 1 kV/µs

Up

600 V

C3 voltage protection level mode core-core at 1 kV/µs

Up

30 V

Response time core-core

ta

1 ns

Response time core-PE

ta

100 ns

Connection (input - output)

RJ45/RJ45

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

Humidity

5 - 95 %

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC000943

Customs tariff number

85363030

EAN

8595090565741


Dimensions:



Write a review

Note: HTML is not translated!
Captcha

Surge protection for Ethernet without PoE, Cat.6A, LPZ1 and higher

0 reviews / Write a review

* Required fields



Related Product

AC diverter ,for suppression of AC voltage

AC diverter ,for suppression of AC voltage

SPD for Cathodic Corrosion Protection System.Combines an AC current diverter and a SPD in one enclos..

Digital tester for status monitor of SPDs

Digital tester for status monitor of SPDs

Measurement of insulation resistance. It can be used to provide a more accurate imagine of the SPD s..

Automatic VLD class 2 tester

Automatic VLD class 2 tester

Portable automatic tester of VLD class 2.Fully automatic measurement.Measurement of Non-triggering v..

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..