For high-speed
general structured cabling networks.
- Combined
(2-stage) SPD for high-speed general structured cabling networks.
- LPZ 0 to LPZ 1
boundary installation.
- To protect
devices working with signals over twisted pairs up to 60V.
Specifications:
Parameter name |
Parameter
value |
|
Type of SPD |
D1,C2,C3 |
|
Location of SPD |
ST
1+2+3 |
|
Mounting |
DIN
rail 35 mm |
|
Maximum operating voltage core-core |
Uc |
60,00
V DC |
Maximum operating voltage pair-pair
(POE) |
Uc |
60,00
V DC |
Nominal load current per core at 25
°C |
IL |
0.5
A |
Treshold frequency core-core |
f |
500.00
MHz |
Insertion attenuation at treshhold
frequency |
2.50
dB |
|
C2 nominal discharge current (8/20
µs) core-core |
In |
0.15
kA |
D1 total discharge current (10/350
µs) cores-PE |
ITotal |
2.00
kA |
C2 total discharge current (8/20 µs)
cores-PE |
ITotal |
10.00
kA |
C2 voltage protection level mode
core-core (@Uoc/In) |
Up |
120,00
V (0,3 kV / 0,15 kA) |
C2 voltage protection level mode
core-PE (@Uoc/In) |
Up |
700,00
V (2,5 kV / 1,25 kA) |
C2 voltage protection level mode
pair-pair (POE) (@Uoc/In) |
Up |
90,00
V (0,3 kV / 0,15 kA) |
C3 voltage protection level mode
core-core (@In - 1 kV/µs) |
Up |
110,00
V (10 A) |
C3 voltage protection level mode
core-PE (@In - 1 kV/µs) |
Up |
500,00
V (10 A) |
C3 voltage protection level mode
pair-pair (POE) (@In - 1 kV/µs) |
Up |
85,00
V (10 A) |
Response time core-core |
ta |
1
ns |
Response time core-PE |
ta |
100
ns |
Connection (input - output) |
RJ
45/RJ 45 |
|
Degree of protection |
IP
30 (without connectors IP 10) |
|
Range of ambient temperatures
(min/max) |
-10
/ 50 °C |
|
Humidity |
15
- 85 % |
|
According to standard |
EN
61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012 |
|
ETIM Class |
EC000943 |
|
Customs tariff number |
85363010 |
|
EAN |
8595090570707 |
Dimensions:
SPD for general structured cabling networks ,60V, LPZ 0-1 and higher
Related Product
Lightning current arrester for coaxial lines (antennas), 360 V DC
Connectors N 50 Ohm.Lightning current arrester for coaxial line.Iinstallation at the boundary of LPZ..
Lightning current arrester for coaxial line, 360 V DC
Connectors N 50 Ohm.Lightning current arrester for coaxial line.Installation at the boundary of LPZ ..
Lightning current arrester for coaxial lines (antennas), up to 250V DC
N connectors, 50 Ohm.Lightning current arrester for coaxial line.Installation at the boundary of LPZ..
Lightning current arrester for coaxial lines (antennas), 250V DC
N connectors, 50 Ohm.Lightning current arrester for coaxial line.Installation at the boundary of LP..