• Module of surge protection, input/output cores, 10 A

/output cores, fault signalling by supply interruption.

  • Surge arrester especially for LED lights.
  • Installation close to protected equipment in LV power circuits.
  • Also for equipment in external part of building with high exposure level (according to IEEE C62.41.2).


Specifications:


Parameter name

Parameter value

Type of SPD

T2,T3

Nominal voltage

Un

230 V AC

Maximum operating voltage

Uc

320.00 V AC

Nominal load current

IL

10.000 A

Type of network

TT|TN

Maximum overcurrent protection

32 A gL/gG or C 32 A

Short-circuit current rating

ISCCR

3.0 kA

Residual current

IPE

0.004 mA

Nominal discharge current (8/20 µs) L-N

In

5.00 kA

Nominal discharge current (8/20 µs) N-PE

In

5.00 kA

Maximum discharge current (8/20 µs) L-N

Imax

10.00 kA

Maximum discharge current (8/20 µs) N-PE

Imax

10.00 kA

Test voltage L-N

Uoc

10.0 kV

Test voltage L-PE

Uoc

10.0 kV

Test voltage N-PE

Uoc

10.0 kV

Voltage protection level mode L-N

Up

1.30 kV

Voltage protection level mode L-PE

Up

1.50 kV

Voltage protection level mode N-PE

Up

1.50 kV

Response time L-N

ta

25 ns

Response time N-PE

ta

100 ns

TOV 5 s L-N

335 V

TOV 5 s L-PE

440 V

TOV characteristic (TOV 5 s)

withstand

TOV 120 min L-N

440 V

TOV characteristic (120 min)

withstand

TOV 200 ms L-PE

1 455 V

TOV 200 ms N-PE

1 200 V

TOV characteristic (TOV 200 ms)

safe failure

Fault indication

loss of voltage, dark grey indication field

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

Humidity

5 - 95 %

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000942

Customs tariff number

85363030

EAN

8595090562450


Dimensions:




Datasheet:

     SP-T2+T3-320/Y-CCC-LED


Write a review

Note: HTML is not translated!
Captcha

Module of surge protection, input/output cores, 10 A

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.


Related Product

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..