• Lightning current and surge arrester for PV systems, 1000 V DC

Visual fault signalling, remote fault signalling.

  • Varistor lightning current arrester and surge arrester in 'Y' connection.
  • For protection of PV systems on the roofs, where the separating spark-over distance is not kept (connection to LPS).
  • Maximum continuous operating voltage for PV application: UCPV ≥ 1.2x UOC STC.


Specifications:


Parameter name

Parameter value

Type of SPD

PV T1, PV T2

Mounting

DIN rail 35 mm

Maximum operating voltage mode +/PE, -/PE

UCPV

1 050.00 V DC

Short-circuit current rating

ISCPV

10 000 A DC

Residual current mode +/PE, -/PE

IPE

1.000 mA AC

Residual current mode +/PE, -/PE

IPE

0.010 mA DC

Total discharge current (10/350 µs)

ITotal(10/350)

12.50 kA

Lightning impulse current (10/350 µs)

Iimp

6.25 kA

Total discharge current (8/20 µs)

ITotal(8/20)

80.00 kA

Nominal discharge current (8/20 µs)

In

20.00 kA

Maximum discharge current (8/20 µs)

Imax

40.00 kA

Voltage protection level mode +/-

Up

3.80 kV

Voltage protection level mode +/PE, -/PE

Up

3.80 kV

Response time

ta

25 ns

Cross-section of connected conductors solid (min)

4.00 mm2

Cross-section of connected conductors solid (max)

35.00 mm2

Cross-section of connected conductors stranded (min)

2.50 mm2

Cross-section of connected conductors stranded (max)

25.00 mm2

Cross-section of remote indication conductors solid (max)

1.5 mm2

Cross-section of remote indication conductors stranded (max)

1.5 mm2

Fault indication

red indication field

Remote indication

potential-free change-over contact

Remote indication contacts

250V/0,5A AC,250V/0,1A DC

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

According to standard

EN 61643-31, IEC 61643-31

ETIM Class

EC001457

Customs tariff number

85363090

EAN

8595090541981


Dimensions:





Datasheet:

     FLP-PV1000/YS

Write a review

Note: HTML is not translated!
Captcha

Lightning current and surge arrester for PV systems, 1000 V DC

0 reviews / Write a review

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.



Related Product

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..

Replacement module for SLP-PV500 V/U.

Replacement module for SLP-PV500 V/U.

Replacement module for SLP-PV1000 V/Y (S).Specifications:Parameter name Parameter..