Fault signalling due to power supply interruption, visual fault signalling.
- Surge protection with integrated RFI filter.
- Installation to LV installations, close to protected equipment.
- For protection of power lines of I&C, electronic security and fire detection systems, etc. against impact of surge voltage and RF disturbance.
- Protection priority.
Specifications:
Parameter name |
Parameter value |
|
Type of SPD |
T3 |
|
Mounting |
DIN rail 35 mm |
|
Nominal voltage |
Un |
230 V AC |
Maximum operating voltage |
Uc |
275.00 V AC |
Nominal load current |
IL |
10.000 A |
Type of network |
TN |
|
Maximum overcurrent protection |
10 A gL/gG or C 10 A |
|
Short-circuit current rating |
ISCCR |
6.0 kA |
Filter attenuation at 1MHz (50 Ω//50 Ω/) unsymmetrical |
30 dB |
|
Nominal discharge current (8/20 µs) L-N |
In |
3.00 kA |
Nominal discharge current (8/20 µs) L+N-PE |
In |
5.00 kA |
Nominal discharge current (8/20 µs) N-PE |
In |
3.00 kA |
Test voltage L-N |
Uoc |
6.0 kV |
Test voltage L+N-PE |
Uoc |
10.0 kV |
Test voltage N-PE |
Uoc |
6.0 kV |
Voltage protection level mode L-N |
Up |
1.20 kV |
Voltage protection level mode L-PE |
Up |
1.50 kV |
Voltage protection level mode N-PE |
Up |
1.50 kV |
Response time L-N |
ta |
25 ns |
Response time N-PE |
ta |
100 ns |
TOV 5 s L-N |
335 V |
|
TOV 5 s L-PE |
440 V |
|
TOV characteristic (TOV 5 s) |
withstand |
|
TOV 120 min L-N |
440 V |
|
TOV 120 min L-PE |
335 V |
|
TOV characteristic (120 min) |
withstand |
|
TOV 200 ms L-PE |
1 200 V |
|
TOV 200 ms N-PE |
1 455 V |
|
TOV characteristic (TOV 200 ms) |
safe failure |
|
Cross-section of connected conductors solid (max) |
6.00 mm2 |
|
Cross-section of connected conductors stranded (max) |
6.00 mm2 |
|
Cross-section of remote indication conductors solid (max) |
1.5 mm2 |
|
Cross-section of remote indication conductors stranded (max) |
1.5 mm2 |
|
Fault indication |
red indication field, supply interruption |
|
Degree of protection |
IP 20 |
|
Range of ambient temperatures (min/max) |
-40 / 80 °C |
|
According to standard |
EN 61643-11:2012, IEC 61643-11:2011 |
|
ETIM Class |
EC000942 |
|
Customs tariff number |
85363010 |
|
EAN |
8595090557241 |
Dimensions:
Surge protection with RFI filter,10 A.
Related Product
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications: Parameter name ..
Replacement module for SLP-PV500 V/U.
Replacement module for SLP-PV1000 V/Y (S).Specifications: Parameter name ..