Applications
These shielded and PVC insulated cables are used as signal transmission cables in industrial applications.
They can be easily used with their flexible construction in narrow applications like: electronic control systems
of computer or audio systems or in communication sector, electronic circuits, measurement devices, machine
design, office equipment, etc. They are used for indoor applications. Screening protects the cable from the outer electrical effects.
Construction
Conductor | Stranded Electrolytic Annealed Copper (IEC /EN 228 / VDE0295 / HD383 / BS 6360 Class 5, 0.34 mm² : Column 2) |
Insulation | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281-TI2), Color Code : DIN 47100 |
Lay-up | Cores stranded in layers |
Separator | Polyester tape |
Drain Wire | Stranded Tinned Copper |
Shielding | AL-PES tape |
Outer Sheath | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281 TM 1) Outer Sheath Color : RAL 7001 Grey |
Reference Standards | VDE 0812 |
Flame Test | IEC / EN 60332-1 , VDE 0482-265-2-1 |
Technical and Electrical Properties (20°C)
Operating Voltage | 0.14 mm²...0.25 mm² | 250 V |
0.34 mm²...1.50 mm² | 300 V / 500 V | |
2.50 mm²................. | 450 V / 750 V | |
Test Voltage | 0.14 mm²...0.25 mm² | 1200 V |
0.34 mm²...1.00 mm² | 1500 V | |
1.50 mm²................ | 2500 V | |
Insulation Resistance | Min. 200 M.Ohm x Km | |
Inductance | Approx. 0.65 mH / Km | |
Current Carrying Capacity | See Technical Data Table 4 | |
Temperature Range | Fixed | -30°C... + 70°C |
Flexible | -5°C... + 70°C | |
Minimum Bending Radius | Fixed | 7.5 x Cable Diameter |
Flexible | 15 x Cable Diameter |
Cross | Conductor Resistance | Capacitance | Capacitance |
0.14 mm² | 138.0 | 80 | 120 |
0.22 mm² | 85.0 | 100 | 150 |
0.25 mm² | 77.8 | 100 | 150 |
0.34 mm² | 56.0 | 100 | 150 |
0.50 mm² | 39.0 | 110 | 170 |
0.75 mm² | 26.0 | 110 | 170 |
1.00 mm² | 19.5 | 120 | 180 |
1.50 mm² | 13.3 | 120 | 1 |
* 2.50 mm² - 4.00 mm² 6.00 mm² and also LSF type of LIY(St)Y cables can be produced as well.
* LIY(St)Y-OZ : black cores with numbers ; LIY(St)Y-JZ : black cores with numbers + one green/yellow core
2 Core Shielded Control Cable 1mm² 305m Roll for Automation.
Related Product
Cable Entry RAL 9011 graphite black (Type 2).
Specification:Cable entry for additional or retro cable input and output installation. Type 1: 183..
Surge arrester for PV systems (both poles), up to 1500 V DC
Pluggable module, visual fault signalling, module locking, remote fault signalling.Varistor surge ar..