Applications
These PVC (screened) cables are used in industrial applications for signal transmission.
They can be easily used with their flexible construction in narrow applications like: electronic
control systems of computer or audio systems or in communication sector, electronic circuits,
measurement devices, machine design, office equipment, etc.
Screening protects the cable from the outer electrical effects.
Construction
Conductor | Stranded Electrolytic Annealed Copper (IEC /EN 228 / VDE0295 / HD383 / BS 6360 Class 5, 0.34 mm² : Column 2) |
Insulation | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281-TI2), Color Code : DIN 47100 |
Lay-up | Cores stranded in layers |
Separator | Polyester tape |
Screen | Tinned Copper Wire Braiding (70% Coverage) (EN 50288) |
Outer Sheath | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281 TM 1) Outer Sheath Color : RAL 7001 Grey |
Reference Standards | VDE 0812 |
Flame Test | IEC / EN 60332-1, VDE 0482-265-2-1 |
Technical and Electrical Properties (20°C)
Operating Voltage | 0.14 mm²...0.25 mm² | 250 V |
0.34 mm²...1.50 mm² | 300 V / 500 V | |
2.50 mm²................. | 450 V / 750 V | |
Test Voltage | 0.14 mm²...0.25 mm² | 1200 V |
0.34 mm²...1.00 mm² | 1500 V | |
1.50 mm²................ | 2500 V | |
Insulation Resistance | Min. 200 M.Ohm x Km | |
Inductance | Approx. 0.65 mH / Km | |
Current Carrying Capacity | See Technical Data Table 4 | |
Temperature Range | Fixed | -30°C... + 70°C |
Flexible | -5°C... + 70°C | |
Minimum Bending Radius | Fixed | 7.5 x Cable Diameter |
Flexible | 15 x Cable Diameter |
Cross | Conductor Resistance | Capacitance | Capacitance |
0.14 mm² | 138.0 | 80 | 120 |
0.22 mm² | 85.0 | 100 | 150 |
0.25 mm² | 77.8 | 100 | 150 |
0.34 mm² | 56.0 | 100 | 150 |
0.50 mm² | 39.0 | 110 | 170 |
0.75 mm² | 26.0 | 110 | 170 |
1.00 mm² | 19.5 | 120 | 180 |
1.50 mm² | 13.3 | 120 | 180 |
2.50 mm² | 7.98 | 140 | 240 |
* 4.00 mm² 6.00 mm² and also LSF type of LIYCY cables can be produced as well.
* LIYCY-OZ: black cores with numbers ; LIYCY-JZ: black cores with numbers + one green/yellow core
305m Braided Shield Control Signal Cable 8 Core 22 AWG.
Related Product
Cabinet Top Cover Miracel W600 D600
or use in conjunction with the CoolBlast® fan topClosed top cover with cable entry for protection ag..
Dual Locking Red Server Power Extension Cable C14 to C13 3ft.
Specifications:Male PlugIEC320 C14 P-Lock to Dual LockFemale ConnectorIEC320 C13 Dual LockVoltage250..
Hydraulic tensioners-puller for overhead lines stringing
Hydraulic machine suitable to operate as a tensioner or as a puller to string or recover t..
Secure IEC C19 Power Cord With UK Plug 2m Black.
UK Plug to IEC Lock C19 Black 2MFully Moulded, Colour: Black , Rated at 13amp..
AED50.00





