• 12 Core Fiber Optic Cable OM1 62.5/125 Outdoor Steel Armored Black
  1. Optical  fibre: Multimode (FOTAG color code)
  2. Tube : PBT Polyester
  3. Waterproofing : Gel
  4. Reinforcement :Water blocking aramid and glass yarns
  5. Inner sheath : Indoor/outdoor LSOH, blue
  6. Armour : Corrugated steel armour             
  7. Outer jacket : HD polyethylene, black.

Main Cable Characteristics

Standards

                                                                       From 4 to 12 fibres cables

Temperature Range

Transport and Storage

-40 / +70 °C

Installation

-5 / +50°C

Operating

-40 / +70°C

Max. Pulling Force (N)

1200

Crush Resistance (N/cm)

900

Min. Bending radius (mm)

150

Standard Packaging

1000 or 2100 m drums

Nominal sheath thickness (mm)

1

Nominal diameter (mm)

10.5

Nominal weight (kg/km)

125

Marking of outer jacket

Manufacturing year – ACOME – fibre count and type – product reference + metric 


Cables and optical fibers

  •  IEC/EN 60793
  •  IEC/EN 60794-1

Cabling Systems

  •  EN 50173
  •  ISO 11801

Applications

  • IEEE 802.3 10|M and 10Gbit
  • IEEE 802.5 Token ring
  • ANSI X3T9-5 (FDDI)
  • ATM (155, 622)

Write a review

Note: HTML is not translated!
Captcha

12 Core Fiber Optic Cable OM1 62.5/125 Outdoor Steel Armored Black

  • AED9.00

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.


Related Product

Cable Drum Lifting Jacks 5T W/Axle.

Cable Drum Lifting Jacks 5T W/Axle.

Cable drum lifting jack is an uncomplicated solution for spooling large drums of power and data cab..

Lightning current arrester , replacement module  for 2-core signalling lines, 230 V DC, max. 1 A

Lightning current arrester , replacement module for 2-core signalling lines, 230 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Galvanised chain rollers

Galvanised chain rollers

Galvanised chain rollers -  ø 32 - ↔ 185 mmSpecificationPart NumberNDimensions (mm)Weight (Kg)J..

Dual Laser Optical Test Source, T2822

Dual Laser Optical Test Source, T2822

This dual optical laser source is a general purpose test source for single mode systems, at 1310-15..