• 6 Core Fiber Optic Data Cable 9/125 for Telecom Networks.

1. Optical fibre : Multimode or singlemode (FOTAG color code)
2. Tube : Thermoplastic material
3. Tube waterproofing : Gel                        
4. Reinforcement : Glass yarns for protection against rodents  (with water swelling yarns) 
5. Outer jacket : Blue LSOH sheath, in accordance with EN 50290-2-27


ACOME cable references


Cable content

Singlemode 9/125* OS1
ACSM2 METRO

6 fibres

N6687


MAIN CABLE CHARACTERISTICS

 

From 2 to 12 fibres cables

Temerature Range

Transport & storage

-40 / +70°C

Installation

-5 / +50°C

Operation

-20 / +70°C

Maximum pulling force (N)

1500

Crush resistance (N/cm)

150

Minimum bending radius (mm)

60

Fire behaviour

Compliant IEC 60332-1

Standard packaging

1000m or 2100m drums

Nominal sheath thickness (mm)

0.8

Nominal diameter (mm)

6.2

Nominal weight (kg/km)

41

Marking of outer jacket

Manufacturing year – ACOME – fibre count & type – product reference + metric

STANDARDS

Cables and optical fibres

  • IEC/EN 60793
  • IEC/EN 60794-1

Cabling systems

  • EN 50173
  • ISO 11801

Applications

  • IEEE 802.3 10M to 10Gbit
  •  IEEE 802.5 Token ring
  •  ANSI X3T9-5 (FDDI)
  • ATM (155, 622, …)

Write a review

Note: HTML is not translated!
Captcha

6 Core Fiber Optic Data Cable 9/125 for Telecom Networks.

  • AED3.40

* Required fields


Terms & Conditions
  • All prices are subject to confirmation and exclude applicable taxes unless stated otherwise.
  • Payment terms are outlined in the respective quotation or invoice.
  • Orders will be processed once payment is confirmed or an approved purchase order is received, where applicable.
  • Prices, availability, and payment terms are subject to change without prior notice.

Related Product

Knürr DI-STRIP® Protector FI / LS (D Schuko – 9, L - 683).

Knürr DI-STRIP® Protector FI / LS (D Schuko – 9, L - 683).

Specification:Protector FI / LS: Fault current switch and circuit breaker. Provides a combination of..

Protective Side Panel For Technical Wall Frame Systems.

Protective Side Panel For Technical Wall Frame Systems.

Design harmonized with Knürr SynergyConsole®Spacious cable management with plenty of space for switc..

VOLTAPOWER • ø 11 mm - Accessories and spare parts

VOLTAPOWER • ø 11 mm - Accessories and spare parts

Starting/Ending threaded ends with M12 thread, for rod ø 11 mm [D] Anfangs/ Endhülse, M12, für Einzi..

Lightning current arrester replacement module,  for 2-core signalling lines, 60 V DC, max. 1 A

Lightning current arrester replacement module, for 2-core signalling lines, 60 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..