2. Tube : Thermoplastic material
3. Tube waterproofing : Gel
4. Reinforcement : Glass yarns for protection against rodents (with water swelling yarns)
5. Outer jacket : Blue LSOH sheath, in accordance with EN 50290-2-27
ACOME cable references
Cable content | Singlemode 9/125* OS1 |
6 fibres | N6687 |
MAIN CABLE CHARACTERISTICS
| From 2 to 12 fibres cables | |
Temerature Range | Transport & storage | -40 / +70°C |
Installation | -5 / +50°C | |
Operation | -20 / +70°C | |
Maximum pulling force (N) | 1500 | |
Crush resistance (N/cm) | 150 | |
Minimum bending radius (mm) | 60 | |
Fire behaviour | Compliant IEC 60332-1 | |
Standard packaging | 1000m or 2100m drums | |
Nominal sheath thickness (mm) | 0.8 | |
Nominal diameter (mm) | 6.2 | |
Nominal weight (kg/km) | 41 | |
Marking of outer jacket | Manufacturing year – ACOME – fibre count & type – product reference + metric | |
STANDARDS
Cables and opticalfibres
- IEC/EN 60793
- IEC/EN 60794-1
Cabling systems
- EN 50173
- ISO 11801
Applications
- IEEE 802.3 10M to 10Gbit
- IEEE 802.5 Token ring
- ANSI X3T9-5 (FDDI)
- ATM (155, 622, …)
8 Core Multimode Fiber Optic Cable LSZH for Indoor Outdoor Use.
Related Product
Lightning current arrester for 2-core signaling lines, replacement module, 24 V DC, max. 2 A
Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..
Multi socket outlet , SDP Type 3 for rack 19"
Visual fault signalling, 3 m power supply cord, CEE 7/7 type plug.Multiple socket outlet with integr..
Deburring tool for plastic pipes ø 28-50mm
Specification0,3 kg..
Cabinet 18U W600 D800 With Back Door S/bolted - RAL7021
DAFCAB racks are designed for installing patch panels, active components, servers etc.Description of..
AED821.00