Applications
These PVC cables are used in industrial applications for signal transmission. They can be easily used with their
flexible construction in narrow applications like: electronic control systems of computer or audio systems
or in communication sector, electronic circuits, measurement devices, machine design, office equipment, etc.
They are for indoor applications.
Construction
Conductor | Stranded Electrolytic Annealed Copper (IEC /EN 228 / VDE0295 / HD383 / BS 6360 Class 5, 0.34 mm² : Column 2) |
Insulation | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281-TI2), Color Code : DIN 47100 |
Lay-up | Cores stranded in layers |
Outer Sheath | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281 TM1) Outer Sheath Color : RAL 7001 Grey |
Reference Standards | VDE 0812 |
Flame Test | IEC / EN 60332-1, VDE 0482-265-2-1 |
Technical and Electrical Properties (20°C)
Operating Voltage | 0.14 mm²...0.25 mm² | 250 V |
0.34 mm²...1.50 mm² | 300 V / 500 V | |
2.50 mm²................. | 450 V / 750 V | |
Test Voltage | 0.14 mm²...0.25 mm² | 1200 V |
0.34 mm²...1.00 mm² | 1500 V | |
1.50 mm²................ | 2500 V | |
Insulation Resistance | Min. 200 M.Ohm x Km | |
Inductance | Approx. 0.65 mH / Km | |
Current Carrying Capacity | See Technical Data Table 4 | |
Temperature Range | Fixed | -30°C... + 70°C |
Flexible | -5°C... + 70°C | |
Minimum Bending Radius | Fixed | 7.5 x Cable Diameter |
Flexible | 15 x Cable Diameter |
Cross Section | Conductor Resistance | Capacitance |
0.14 mm² | 138.0 | 80 |
0.22 mm² | 85.0 | 100 |
0.25 mm² | 77.8 | 100 |
0.34 mm² | 56.0 | 100 |
0.50 mm² | 39.0 | 110 |
0.75 mm² | 26.0 | 110 |
1.00 mm² | 19.5 | 120 |
1.50 mm² | 13.3 | 120 |
2.50 mm² | 7.98 | 14 |
* 4.00 mm² 6.00 mm² and also LSF type of LIYY cables can be produced as well.
* LIYY-OZ: black cores with numbers ; LIYY-JZ: black cores with numbers + one green/yellow core
Heavy-Duty 2 Core Control Cable 2.5mm² PVC Sheathed 305m.
Related Product
Floor Box Cavity Type 3 Compartment 300x200x100mm.
3 Compartment 100mm Deep Cavity Service Box3 Compartment Cavity Service Box.20mm and 25mm Knockouts...
Surge protection with RFI filter,10 A.
Fault signalling due to power supply interruption, visual fault signalling.Surge protection with int..
Replacement module for BDG-230-V/1-xRx
SPD - for data, signalling and telecommunications lines / I&C / Spare modulesReplacement module ..
Patch Cord Cat 6A SFTP 24AWG 10M LSOH-Grey Webb.
WEBB CAT6 Screened foiled S/FTP patch cord are designed to meet and exceed ANSI/TIA/EIA 568B stand..