Applications
These shielded and PVC insulated cables are used as signal transmission cables in industrial applications.
They can be easily used with their flexible construction in narrow applications like: electronic control systems
of computer or audio systems or in communication sector, electronic circuits, measurement devices, machine
design, office equipment, etc. They are used for indoor applications. Screening protects the cable from the outer electrical effects.
Construction
Conductor | Stranded Electrolytic Annealed Copper (IEC /EN 228 / VDE0295 / HD383 / BS 6360 Class 5, 0.34 mm² : Column 2) |
Insulation | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281-TI2), Color Code : DIN 47100 |
Lay-up | Cores stranded in layers |
Separator | Polyester tape |
Drain Wire | Stranded Tinned Copper |
Shielding | AL-PES tape |
Outer Sheath | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281 TM 1) Outer Sheath Color : RAL 7001 Grey |
Reference Standards | VDE 0812 |
Flame Test | IEC / EN 60332-1 , VDE 0482-265-2-1 |
Technical and Electrical Properties (20°C)
Operating Voltage | 0.14 mm²...0.25 mm² | 250 V |
0.34 mm²...1.50 mm² | 300 V / 500 V | |
2.50 mm²................. | 450 V / 750 V | |
Test Voltage | 0.14 mm²...0.25 mm² | 1200 V |
0.34 mm²...1.00 mm² | 1500 V | |
1.50 mm²................ | 2500 V | |
Insulation Resistance | Min. 200 M.Ohm x Km | |
Inductance | Approx. 0.65 mH / Km | |
Current Carrying Capacity | See Technical Data Table 4 | |
Temperature Range | Fixed | -30°C... + 70°C |
Flexible | -5°C... + 70°C | |
Minimum Bending Radius | Fixed | 7.5 x Cable Diameter |
Flexible | 15 x Cable Diameter |
Cross | Conductor Resistance | Capacitance | Capacitance |
0.14 mm² | 138.0 | 80 | 120 |
0.22 mm² | 85.0 | 100 | 150 |
0.25 mm² | 77.8 | 100 | 150 |
0.34 mm² | 56.0 | 100 | 150 |
0.50 mm² | 39.0 | 110 | 170 |
0.75 mm² | 26.0 | 110 | 170 |
1.00 mm² | 19.5 | 120 | 180 |
1.50 mm² | 13.3 | 120 | 180 |
* 2.50 mm² - 4.00 mm² 6.00 mm² and also LSF type of LIY(St)Y cables can be produced as well.
* LIY(St)Y-OZ : black cores with numbers ; LIY(St)Y-JZ : black cores with numbers + one green/yellow core
4 Core Shielded Control Cable 100m Roll White for Signal Wiring.
Related Product
Light Source 850nm With SC Adapter
The LS-800 optical Light Source is a small size low cost item which fulfils all necessary technical ..
AED6,040.00
PDU 12Way Vertical Filtered - RAL7021
A high quality range of horizontal and vertical power distribution units with angled sockets (vertic..
AED150.00
Lightning current and surge arrester ,TN-C, 37.5 kA (10/350 µs), 180 kA (8/20 µs)
Pluggable module, visual fault signalling, module locking.Three-pole varistor lightning current ar..
Adjustable boom with aluminium cable roller
Specificationø 210 - ø 110 ↔ 110 mm<-->kg180-240cm23..