Applications
These PVC (screened) cables are used in industrial applications for signal transmission.
They can be easily used with their flexible construction in narrow applications like: electronic
control systems of computer or audio systems or in communication sector, electronic circuits,
measurement devices, machine design, office equipment, etc.
Screening protects the cable from the outer electrical effects.
Construction
Conductor | Stranded Electrolytic Annealed Copper (IEC /EN 228 / VDE0295 / HD383 / BS 6360 Class 5, 0.34 mm² : Column 2) |
Insulation | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281-TI2), Color Code : DIN 47100 |
Lay-up | Cores stranded in layers |
Separator | Polyester tape |
Screen | Tinned Copper Wire Braiding (70% Coverage) (EN 50288) |
Outer Sheath | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281 TM 1) Outer Sheath Color : RAL 7001 Grey |
Reference Standards | VDE 0812 |
Flame Test | IEC / EN 60332-1, VDE 0482-265-2-1 |
Technical and Electrical Properties (20°C)
Operating Voltage | 0.14 mm²...0.25 mm² | 250 V |
0.34 mm²...1.50 mm² | 300 V / 500 V | |
2.50 mm²................. | 450 V / 750 V | |
Test Voltage | 0.14 mm²...0.25 mm² | 1200 V |
0.34 mm²...1.00 mm² | 1500 V | |
1.50 mm²................ | 2500 V | |
Insulation Resistance | Min. 200 M.Ohm x Km | |
Inductance | Approx. 0.65 mH / Km | |
Current Carrying Capacity | See Technical Data Table 4 | |
Temperature Range | Fixed | -30°C... + 70°C |
Flexible | -5°C... + 70°C | |
Minimum Bending Radius | Fixed | 7.5 x Cable Diameter |
Flexible | 15 x Cable Diameter |
Cross | Conductor Resistance | Capacitance | Capacitance |
0.14 mm² | 138.0 | 80 | 120 |
0.22 mm² | 85.0 | 100 | 150 |
0.25 mm² | 77.8 | 100 | 150 |
0.34 mm² | 56.0 | 100 | 150 |
0.50 mm² | 39.0 | 110 | 170 |
0.75 mm² | 26.0 | 110 | 170 |
1.00 mm² | 19.5 | 120 | 180 |
1.50 mm² | 13.3 | 120 | 180 |
2.50 mm² | 7.98 | 140 | 240 |
* 4.00 mm² 6.00 mm² and also LSF type of LIYCY cables can be produced as well.
* LIYCY-OZ: black cores with numbers ; LIYCY-JZ: black cores with numbers + one green/yellow core
305m Braided Shield Control Signal Cable 8 Core 22 AWG.
Related Product
Cabinet 48U W600 D1100 F/Supervented R/Ver.Div Door -9005
The OPTIMAL ROF rack is designed to cope with the demanding needs of IT equipment within a data cent..
Module Euro RJ45 CAT6 50x25mm White - Webb
FeaturesComplete outlet if combined with faceplate and back boxDesigned for use with 110 punch-down ..
Perforated rear panel 90° / 90° trapezoid (D- 1050,H-450).
Specification:Perforated rear panels fit W630 and W1230 Basic Frames, 45°, 90° and 90° Trapezoid Co..
Tiltable Control Room Desk Extension Shelf With Cable Trough.
Height adjustable and tiltableCan be upgraded at any timeHeight variable for exact adjustment to ope..