- Optical fibre : Singlemode (FOTAG color code)
- Tube : Thermoplastic material
- Tube waterproofing : Gel
- Reinforcement : Glass yarns for protection against rodents(with water swelling yarns)
- Outer jacket : Blue LSOH sheath, in accordance with EN 50290-2-27
Main Cable Characteristics
| From 2 to 12 fibres cables | |
Temperature Range | Transport and Storage | -40 / +70 °C |
Installation | -5 / +50°C | |
Operating | -20 / +70°C | |
Max. Pulling Force (N) | 1500 | |
Crush Resistance (N/cm) | 150 | |
Min. Bending radius (mm) | 60 | |
Fire Behavior | Compliant IEC 60332-1 | |
Standard Packaging | 1000m or 2100 m drums | |
Nominal sheath thickness (mm) | 0.8 | |
Nominal diameter (mm) | 6.2 | |
Nominal weight (kg/km) | 41 | |
Marking of outer jacket | Manufacturing year – ACOME – fibre count and type – product reference + metric | |
Standards
Cables and optical fibers
- IEC/EN 60793
- IEC/EN 60794-1
Cabling Systems
- EN 50173
- ISO 11801
Applications
- IEEE 802.3 10|M and 10Gbit
- IEEE 802.5 Token ring
- ANSI X3T9-5 (FDDI)
- ATM (155, 622)
4 Core Single Mode Fiber Optic Cable G652 Indoor Outdoor.
Related Product
Replacement module for BDM-012-V/2-(F)Rx
SPD - for data, signalling and telecommunications lines / I&C / Spare modulesReplacement module ..
Knürr Elicon® Working Level (W2000,H900).
Specification:Working level designed as sliding section for convenient access to the horizontal cab..
Basic Wall Mount Frame For Technical And Control Centers.
Easy flat screen mounting between the monitor wall vertical extrusionsStable monitor hang-on with ad..
Pipe pressure measuring device from 0 to 10 Bar
SpecificationOutletskg1215..