Category 6 U/UTP Patch Cords
Unshielded Twisted Pair (UTP) Category 6 Patch Cord conforms to ANSI/TIA/EIA-568-B.2-1, ISO/IEC 11801 2nd
edition (2002) and CENELEC EN50173 (2002) for Category 6/Class E. It has been tested up to 250 MHz, and
is designed for high speed protocols such as ATM 622 Mbps and Gigabit Ethernet 1000 Mbps applications.
The patch cord is comprised of flexible patch cable and is terminated with two modular plugs along with
moulded snag-less boots.
Features & Benefits
- Snagless design prevents locking tabs breaking off
- 4 pairs twisted pair cable
- Provides enhanced EMC protection and improved alien crosstalk performance
- All cables meet or exceed the requirement proposed by TIA /EIA 568 B .2 ,ISO/IEC 11801 Category 6
- Pre-terminated with 8W plugs
- Available in variety of lengths and colours
- the cross frameworks are stripped to match corresponding colour pairs
- Backwards compatible with Category 5e
Application
- POTS, T1&Tq fractional
- 52/155 Mbps ATM (ATM Forum)
- ASDN basic & primary rate
- 100 BASE-T4 (Fast Ethernet)
- 4/16 Mbps Token Ring (IEEE802.5)
- 00 VG-Any LAN (IEEE802.12)
- 10 BASE-T (IEEE802.3)
- 100 BASE-T (Fast Ethernet)
- 100 Mbps TP-PMD
- 1Gbps Ethernet
Mechanical Characteristics
Cable | |
Conductor Size (AWG) | 24 stranded bare copper |
Dielectric Material | PE |
Diameter of Dielectric Core | 7*0.2mm |
External Diameter | 5.8±0.2mm |
Sheath Material | PVC or LSZH |
Temperature Range | -20°C to +60°C |
| Plug |
Operating Life | 750 Insertion Cycles |
Contact Material | Phosphor Bronze |
Contact Plating | 60 micro-inch Gold |
Electrical Characteristics
Voltage | 150V |
Current | 1.5A |
Contact Resistance | Max 20mΩ |
Insulation Resistance | 500mΩ |
Dielectric Withstanding Voltage | 1000V RMS |
Operating Temperature | -40°C to +85°C |
Patch Cord CAT6 UTP 24AWG 3m LSZH - Grey
Related Product
IEC 320 C20 Plug to IEC 320 C19 Connector WS-Lock Blue 4.5Mtr / 15Ft 20a/250v 12/3 SJT
Specifications:Male PlugC20Female ConnectorIEC320 C19Voltage250 VoltsAmperage20 AmpsCable Length4.5 ..
Short-circuiting module for SPDs type DM…-V/
SPD - for data, signalling and telecommunications lines / I&C / Accessories for I&CShort-cir..
ERGOCON WorkStation _ Control Room Console _ Workstation Technology Cabinet _ W3100 D1100 _ Curved
Workstation Technology Cabinet:- Maximum technical integration for tower or 19” workstation re..
Mountpost 41U Miracel Steel (2/set)
For front and rear installation in the rack Caged nut mountable in HU increments (19”)&nb..