• 4 Core Single Mode Fiber Optic Cable G652 Indoor Outdoor.
  1. Optical fibre : Singlemode (FOTAG color code)
  2. Tube : Thermoplastic material
  3. Tube waterproofing : Gel                         
  4. Reinforcement : Glass yarns for protection against rodents(with water swelling yarns)       
  5. Outer jacket : Blue LSOH sheath, in accordance with EN 50290-2-27

 Main Cable Characteristics

 

From 2 to 12 fibres cables

Temperature Range

Transport and Storage

-40 / +70 °C

Installation

-5 / +50°C

Operating

-20 / +70°C

Max. Pulling Force (N)

1500

Crush Resistance (N/cm)

150

Min. Bending radius (mm)

60

Fire Behavior

Compliant IEC 60332-1

Standard Packaging

1000m or 2100 m drums

Nominal sheath thickness (mm)

0.8

Nominal diameter (mm)

6.2

Nominal weight (kg/km)

41

Marking of outer jacket

Manufacturing year – ACOME – fibre count and type – product reference + metric


Standards

Cables and optical fibers

  • IEC/EN 60793
  • IEC/EN 60794-1

Cabling Systems

  • EN 50173
  • ISO 11801

Applications

  •  IEEE 802.3 10|M and 10Gbit
  •  IEEE 802.5 Token ring
  •  ANSI X3T9-5 (FDDI)
  • ATM (155, 622)

Write a review

Note: HTML is not translated!
Captcha

4 Core Single Mode Fiber Optic Cable G652 Indoor Outdoor.

  • AED2.80

* Required fields


Terms & Conditions
  • All prices are subject to confirmation and exclude applicable taxes unless stated otherwise.
  • Payment terms are outlined in the respective quotation or invoice.
  • Orders will be processed once payment is confirmed or an approved purchase order is received, where applicable.
  • Prices, availability, and payment terms are subject to change without prior notice.

Related Product

Cable V Guide And Run-off Frame Steel Cap.300daN.

Cable V Guide And Run-off Frame Steel Cap.300daN.

Cable run-off frame from the drum, fit for installations cables/pipe with ø 380 mm max. Composed..

Lightning current arrester for 2-core shielding floating signaling lines, replacement module, 48 V DC, max. 2 A

Lightning current arrester for 2-core shielding floating signaling lines, replacement module, 48 V DC, max. 2 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT...

19 Inch Cabinet Side Cover - Heavy Duty 27U Rack Panel

19 Inch Cabinet Side Cover - Heavy Duty 27U Rack Panel

19“ Technology Side Panel HU27 D HU Order no. UP ..

Locking C13 IEC Power Connector - Rewireable Plug.

Locking C13 IEC Power Connector - Rewireable Plug.

IEC Lock+ Rewireable - the world's first locking rewireable C13 IEC connector. Designed to guard aga..

AED19.00