OPTICAL CABLE MINI BREAK-OUT - 2 to 24 SINGLEMODES FIBERS 9/125 - IEC 60794-1-E3
INDOOR/OUTDOOR
1. Optical fibers : Fibers insulated diameter 900µm (tight)
2. Strength members : Glass yarns
3. Rip cord : Blue halogen flame retardant compound
Outer Outer Ø = 6.6 mm
Sheath Thickness = 0.8 mm
Main Cable Characteristics
Temperature Range | Transport and Storage | -30 / +70 °C |
Installation | -5 / +50°C | |
Operating (1) | -10 / +60°C | |
Maximum pulling force (1) Fibre elongation ≤ 0.5 % ; Reversible delta Alpha | 500N | |
Crush Resistance (N/cm) (1) | 200 | |
Crush resistance without fibre break | 900 N/cm | |
Minimum static bending radius (1) | 10 x Ø | |
Minimum kink diameter | 10 x Ø | |
Fire resistance | Compliant | |
Nominal câble weight | 22 kg/km | |